USING THE MACHINE
the display will show all zeros for about 3
seconds, after which the battery voltage value
will be shown.
Let at least three seconds pass after you have
again.
Check the battery charge shown on the
machine's display.
The display has two functions: Voltmeter and
Hour meter.
The voltmeter incorporates an undervoltage
shutdown function that automatically disables
all services except for drive when the battery
drops to a voltage of 20.5V (the BATTERY
display).
In this case, recharge the battery (see the
chapter "BATTERY MAINTENANCE AND
CHARGING" and the battery user manual).
can now resume.
To start the machine, select forward or reverse
gear using the selector on the steering wheel
and press the accelerator pedal.
AUTO-POWER ON/OFF
The machine is equipped with an automatic
Selecting one of the three work programs, P1,
P2 or P3 temporarily activates the following
functions: centre brush, suction, side brushes;
the LED for the selected program lights up
together with the centre brush LED.
If the accelerator pedal is not pressed, after
a few seconds the functions will stop and the
AUTO-POWER-OFF mode.
All of the functions are automatically
reactivated whenever the operator presses the
accelerator pedal.
By releasing the accelerator, all the functions,
except for the combustion engine, are
automatically deactivated.