TROuBLES-REMEDIES
Sudden Starts. If the power is on to the pump when thermal overload resets, the pump may start without
warning. If you are working on the pump, you may get an electrical shock or the impeller may catch fingers or tools.
Disconnect the power before servicing the pump.
A. Pump fails to operate:
B. Pump fails to empty sump:
C. Pump will not shut off:
Limited Warranty
Myers
warrants to the original consumer purchaser ("Purchaser" or "You") of the products listed below, that they will be free from defects in material and
®
workmanship for the Warranty Period shown below.
Product
Jet pumps, small centrifugal pumps, submersible pumps and related accessories
Fibrewound Tanks
Steel Pressure Tanks
Sump/Sewage/Effluent Products
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
Wastewater Solids Handling Pumps
Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional
information, please refer to the applicable standard limited warranty featured in the product manual.
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper
maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that
three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.
Your only remedy, and MYERS's only duty, is that MYERS repair or replace defective products (at MYERS's choice). You must pay all labor and shipping charges
associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be
accepted if received after the Warranty Period has expired. This warranty is not transferable.
MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT
LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES
SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above
limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.
This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.
1. Check to be sure that power cord is securely plugged into outlet or securely wired
into controller or switch box. Disconnect power to outlet before handling pump
or motor.
2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
4. Check to be sure that 3/16" (5mm) vent hole in discharge pipe is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Disconnect the pump from the power source for a minimum of 30 minutes to allow
the motor to cool and to protect yourself from sudden starts. See Warning above.
Check for the cause of overheating. Pump is running dry because the float switch
is caught up on something. Inlet pipe is plugged. Outlet pipe is plugged.
1. Be sure all valves in discharge pipe are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
1. Check switch or controller automatic floats for proper operation and location.
See installation instructions for switch/controller.
2. If pump is completely inoperative or continues to malfunction, consult your
local serviceman.
F.E. MYERS
293 Wright Street, Delavan, WI 53115
Phone: 888-987-8677 • Fax: 800-426-9446 • www.femyers.com
In Canada: 490 Pinebush Road, Unit 4, Cambridge, Ontario N1T 0A5
Phone: 800-363-7867 • Fax: 888-606-5484
Warranty Period
whichever occurs first:
12 months from date of original installation,
or 18 months from date of manufacture
5 years from date of original installation
5 years from date of original installation
12 months from date of original installation,
or 36 months from date of manufacture
12 months from date of original installation,
or 18 months from date of manufacture
24 months from date of original installation,
or 30 months from date of manufacture
12 months from date of shipment from factory
or 18 months from date of manufacture
6