StAnD - By
The Stby function is used if immediate stove switch-off is required when temperature has been
reached.
The STBY function can be set at oN or oFF using the procedure that will be described.
in the factory the StBy function is always set at OFF (indicator off)
STBY FUNCTIoN SET aT oN
If the Stby function is active (oN), when the stove reaches the room temperature set exceeding it by 2°C, it will switch off
after a factory set delay time, displaying STaND - BY.
When the room temperature is 2°C lower than the setting, the stove will start to work again at the power set on the display,
viewing Work.
STBY FUNCTIoN SET aT oFF (FaCTorY SETTINg)
If the Stby function is not active (oFF), if the stove reaches the room temperature set, it will go to minimum, modulating and
displaying MoDULaTE. When the room temperature is lower by 2°C than the setting, the stove will start to work again at
the power set on the display, showing Work.
CoNTroLS ProCEDUrE
Press key 5 for a few seconds, until the text SET CLoCk appears.
Press key 3 three times UNTIL USEr.
Press key 5 twice.
Select "oN" with keys 2 or 3 to activate or "oFF" to deactivate.
Press key 1 several times to confirm and exit the Menu.
reSet
allows to reset all values modifiable by the user to the default values.
The modified data are:
SET TEMPEraTUrE = 35°C
SET PoWEr = 5
ENaBLE CHroNo = oFF
STarT Prg1=oFF
SToP Prg1 = oFF
MoNDaY Prg1 = oFF
.......all chrono parameters oFF
PELLET = 00%
STaND BY = oFF
cHrOnO
The chrono allows to program 2 time spans within a day to use every day of the week.
the switch-on and switch-off time can be set in every time span. along with the days of use
of the programmed time span.
rECoMMENDaTIoNS
The ignition and switch-off times must be within the arc of
one day, from 0 to 24 and not over several days:
Before using the chrono function, set the current day and
time. Therefore check that the points listed in the "Set clock"
sub-chapter have been followed, so that the chrono function
works. aside from programming it, activate it as well.
Example:
cOrrect
Switch-on time 07:00
Switch-off time 18:00
Switch-on time 22:00
incOrrect
Switch-off time 05:00
engLiSH