Espa EQUAL COMPLET Manual De Instalación Y Mantenimiento página 32

Sistema de dosificación de reactivos para piscinas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION AND MAINTENANCE MANUAL
EN
F9 Manual function. Tests. Priming the
pumps.
Press the F key until you reach F9 MANUAL FUNCTION.
Press ENTER in order to enter this function.
The following options appear:
FUNCTION. MANUAL
de-activated
FUNCIÓN. MANUAL
only pH pump
Select the option desired using the arrows.
Press ENTER to validate.
8. MAINTENANCE
• Check regularly that values correspond between the
estimated reading of ClF from the panel with a direct
analysis of the water in the pool.
• Clean the probes of any incrustations or layers of dirt.
• Clean the entry filter, proceeding as is indicated in
Figure 14:
• Remove the nut from the earth point.
• Remove the plastic restraining bolt.
• Remove the filter with care so as to conserve the ring
seals.
• Clean the filter with plentiful amounts of water.
• EQUAL Complet equipment can check the reliability
and quality of the pH and Redox probes. If quality values
are lower than 30% the replacement of the probe is
recommended.
• pH and Redox probes are not included in the
manufacturer's guarantee.
32
FUNCTION. MANUAL
Only Cl pump
FUNCIÓN. MANUAL
pH pump and CI
Fig. 14

Publicidad

Tabla de contenido
loading

Tabla de contenido