Notes About Connections - Nice MINDY A6-A6F Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English
The following terminals are found only on the A700F and A6F version:
12-13
: Electric lock
You will find the following terminals only on the A700F version:
14-15
: Phototest
16
: Common
17
: C1 limit switch
18
: A1 limit switch
19
: C2 limit switch
20
: A2 limit switch
21-22
: 24 Vac
23
: Common
24
: Gate Open Indicator
25
: Stop
26
: Photocell
27
: Photocell 1
28
: Step-by-Step
You will find the following terminals only on the A700F version:
29
: Open
30
: Close
41-42
: 2° Radio Ch
43-44
: Antenna
There are an additional two slots on the unit card for optional cards:
RADIO
PIU'
We recommend waiting until installation is complete to plug in the optional cards RADIO or PIU' and only after having checked
that the system is working properly. The optional cards are not necessary for the working of the system and if they are used they
make troubleshooting more complex.

2.4) NOTES about CONNECTIONS:

For the most part, connections are easy; a lot of them are direct connections to a single user point or contact but some are a little
more complex:
All the single-phase asynchronous motors need a capacitor for them to work properly; some gearmotors like, for example the
PLUTO PL 4000 model made by Nice have this capacitor already connected inside while others have to have the capacitor
connected externally like, for instance, the METRO ME 3000 model, also made by Nice. In this case, the capacitor must be
connected between the motor's OPEN and CLOSE phases. To be more practical the capacitor should be connected directly
inside the unit in the spaces left for it.
26
= 12 Vac output to activate the electric lock, 25 W maximum power
= 24 Vac output to feed photoelectric cell transmitters, 100 mA max.
= Common for limit switch inputs (same as the other common, terminal 23)
= Close limit switch input for motor 1
= Open limit switch input for motor 1
= Close limit switch input for motor 2
= Open limit switch input for motor 2
= 24 Vac output to feed accessories (Photocell, Radio, etc.) 200 mA max.
= Common for all inputs (terminal 22 can also be used as Common)
= 24 Vac output for gate open indicator, 2 W max. indicator power
= Input with STOP function (Emergency, shutdown or extreme safety)
= Input for safety devices (photoelectric cells, pneumatic edges)
= Input for another safety device (photoelectric cells, pneumatic edges)
= Input for cyclic functioning (OPEN STOP CLOSE STOP)
= Input for opening (it can be controlled by a timer)
= Input for closing
= Output for the second radio receiver channel if there is one
= Input for the radio receiver antenna
= Slot for Nice radio receivers
= Slot for PIU' expansion card (only on the A700F version)