Mosa GE 6000 SX Manual De Instrucciones página 42

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

I
Technical data
GB
F
Technical data
A.C. GENERATOR
*Three-phase power Stand-by
**Three-phase power PRP
*Single-phase power Stand-by
**Single-phase power PRP
*Single-phase power Stand-by
**Single-phase power PRP
Frequency
Power factor (cos ϕ)
ALTERNATOR
Type
Insulating class
ENGINE
Mark / Model
Type / Cooling system
Cylinders / Displacement
Net power Stand-by
Net power PRP
Speed
Fuel consumption
Engine oil capacity
Starter
GENERAL SPECIFICATIONS
Fuel tank capacity
Running time (75% of PRP)
Protection
*Dimensions max. Lxwxh
*Weight (dry)
Measured acoustic power LwA (LpA pression)
Guaranteed acoustic power LwA (LpA pression) 93 dB(A) (68 dB(A) @ 7 m)
* Dimensions and weight are inclusive of all parts.
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power PRP) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the PRP.
It's admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
(L
Acoustic Noise Level
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(L
)
of 95 dB(A)
WA
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
PLEASE NOTE: the symbol
according to 2000/14/CE directive.
GE 6000 SX/GS
GE 6000 SX/GS-AVR
-
-
5.7 kVA (5.1 kW) / 230 V / 24.8 A
5 kVA (4.5 kW) / 230 V / 21.7 A
5.7 kVA (6 kW) / 115 V / 49.6 A
5 kVA (5 kW) / 115 V / 43.5 A
50 Hz
0.9
self-excited, self-regulated, brushless
Single-phase, synchronous
H
206 Kg
92 dB(A) (67 dB(A) @ 7 m)
ACOUSTIC POWER LEVEL
)
- Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
WA
when with acoustic noise values, indicates that the device respects noise emission limits
2000 / 14 / CE
YANMAR / L 100 N
Diesel 4-Stroke / Air
1 / 435 cm
3
6.5 kW (8.8 HP)
5.7 kW (7.7 HP)
3000 rpm
1.2l/h
1.6 l
Electric
23 l
19 h
IP 23
1020x645x930
2000 / 14 / CE
OUTPUT
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
GE 6000 SX/GS
GE 6500 SX/GS
GE 6500 SX/GS
6.5 kVA (5.2 kW) / 400 V / 9.4 A
5.7 kVA (4.6 kW) / 400 V / 8.2 A
-
4 kVA / 230 V / 17.4 A
-
-
50 Hz
0.8
self-excited, self-regulated, with brush
Three-phase, synchronous
H
206 Kg
91 dB(A) (66 dB(A) @ 7 m)
92 dB(A) (67 dB(A) @ 7 m)
2000 / 14 / CE
M
1.5
REV5-12/12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ge 6000 gsGe 6000 sx-avrGe 6000 gs-avrGe 6500 sxGe 6500 gs

Tabla de contenido