Before Testing; Assembly Instructions - Master Forge GR2045401-MF-00 Manual Del Usuario

Parrilla con 6 quemado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BEFORE TESTING

Make sure that all packing material is removed from the grill including the burner
tie-down straps.
Make a soap solution of one part liquid detergent and one part water. You will need a
spray bottle, brush, or rag to apply the solution to the fittings. For the initial leak test,
make sure the LP cylinder is full.
WARNING
DO NOT SMOKE WHILE CONDUCTING LEAK TEST
NEVER PERFORM LEAK TEST WITH AN OPEN FLAME
If it is evident there is excessive abrasion or wear, or the hose is cut, it must be
replaced prior to the appliance being operational. The replacement hose shall be
specified the by manufacturer.
TO TEST
1. Make sure the control valves are in the "OFF" position,
and turn on the gas supply.
2. Check all connections from the gas cylinder, LP gas
regulator and supply valve up to and including all the
connections to the pipe that go to the burners (the
diagram shows the point where the soap water
mixture is being applied). Soap bubbles will appear
where a leak is present.
3. If a leak is present, immediately turn off the gas
supply and tighten the leaky fittings.
4. Turn the gas back on and recheck.
5. If it is evident there is excessive abrasion or wear, or
the hose is cut, it must be replaced prior to the
outdoor cooking gas appliance being put into
operation. The replacement hose assembly shall
be that specified by the manufacturer. Contact
customer service department at 1-800-963-0211, 8 a.m. - 6 p.m., EST, Monday -
Thursday; 8 a.m. - 5 p.m., EST, Friday.

ASSEMBLY INSTRUCTIONS

Symbol: Some steps may require the assistance of a friend.
GR2045401-MF-00 / GR2045402-MF-00
8
20121205

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Gr2045402-mf-00

Tabla de contenido