Installation Procedures
Installation Confi guration
Step 2 – Electrical Connections
Terminal Block X2
1
BLK
Transducer
WHITE
Connectors
RED
NOTE 1: J1, J2 factory installed jumpers.
NOTE 2: Motor thermistor installed in back of ODP motor.
NOTE 3: Input supply voltage is measured phase to phase.
AquaBoost I
Connection / Wiring Diagrams
Input/Output P ower Wiring
1Ø
208-230 Volt
Supply
Control Wiring
2
3
4
5
6
7
J1
J2
GRN
GND
RED
U
BLUE
V
BLK
W
AQUABOOST
3Ø Motor 230V
CONTROLLER
Output
GND
L
1
GRN
BLK
BLK
8
9
10
11
12
PURPLE
PURPLE
8
N
Motor Thermistor
Connection