In order to achieve the degree of safety required by existing laws and standards please read the following instructions carefully.
Make all the connections in the terminal block after carefully reading the instructions given in this manual and observing the general
1)
rules and technical standards governing electrical systems.
Upstream from the installation, fi t an omnipole miniature circuit breaker with a contact gap of at least 3 mm.
2)
3)
If there isn't one already, install a residual current device with a threshold of 30 mA.
4)
Check the effectiveness of the grounding system and connect to it all the parts of the automation fi tted with a terminal or grounding
cable.
5)
Fit at least one external warning device, such as a traffi c light or fl ashing light, along with a warning or danger sign.
6)
Fit all the safety devices required by the type of installation, taking into consideration the risks it can cause.
7)
Separate the power lines (min. sect. 1.5 mm
8)
Fit jumpers in the N.C. inputs not used.
Set in series any contacts to be connected in series with the same N.C. input.
9)
Set in parallel the inputs connected to the same N.O. input.
10)

10. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS

LINE 230V
N
1
230V 50/60Hz power supply with mov internal protection and 6,3A fuse (5x20).
230 V ~
Connect the phase and neutral as shown on the screen printing while ground should be connected to the EARTH Faston
P
2
terminals. Use a cable type H05VV-F 2x1.5+E min.
11
FLASHING LIGHT: YELLOW at 230V 100W max
Unit to signal the automatism is operating; model SLR.
SLR
Connect terminals 11 and 12 of the unit to terminals N and F respectively of the fl ashing lamp.
12
The output is protected by a 250 mA fuse (F2). Note: Only use 230Vac max 40W lamps.
AP
4
MOTOR
C
M
5
Motor output 230V: BROWN-4; BLUE-5; BLACK-6.
The earth cable must be connected to the EARTH
CH
6
44
USER
USER
Contact for external use, designed to signal any operation of the photocell.
The contact breaker is programmed by dip-switch 6. Circuit breaker rating: 230 Vac, 4 A.
45
NOTE: The output in the DD3 versions is used to control the electric lock.
LIGHTS
A 24 Vac output is made available to power the function indicators of the barrier.
34
Connect the indicator cables in parallel to terminals 34-35. Output is programmed by dip-switch 9 .
LIGHTS
Check: all the indicators should ligth when status led LGT lights.
35
The output is active immediately after the purchase of a barrier with lights or subsequently after the purchase of the
"light arrangement" accessory.
14
24 V
24 V
24Vac output to power the safety and control accessories like photocells or radio receivers.
15
17
24 V
24 V
24Vac output to power the safety and control accessories like photocells or radio receivers.
16

9. INSTALLATION SAFETY

) from the low-voltage signal lines (min. sect. 0,5 mm
2
10.1 POWER TERMINAL BLOCK
10.2 LOW VOLTAGE OUTPUT TERMINAL BLOCK
terminals.
- 13 -
) in the ducts.
2
terminals 1 - 2 (230V)
terminals 11 - 12 (SLR)
terminals 4 - 5 - 6 (ENGINE)
terminals 44 - 45
terminals 34 - 35
terminals 14 - 15
terminals 17 - 16