HELIOS ELECTRIC INFRARED
WEATHER PROOF IP 23 MODEL – 1500/2000 Watt
PROTECTED AGAINST RAIN
WP 2000 is an extremely versatile heater working with infrared rays.
It can be used in different situations and above all it is a very useful thermal support for your different jobs. Its heat is
immediate and the electricity consumption is very low, it takes a little space although it heats a very wide area.
WP 2000 is built and developed with the best quality components in accordance to the prevailing to the prevailing
legal regulations and certified for safety in use.
WARNING:
The safety of the instrument is guaranteed only with proper use of the following instructions. It is therefore necessary
to keep them for future reference. Disconnect from main electricity supply during installation and/or replacement of
the bulb.
Classe I
220-240V 50/60Hz
CONSTRUCTION:
•Steel body in aluminium alloy, kiln varnishing with epoxy powders.
•Reflecting parabola made of polished ultra pure aluminium, anodically oxidised.
•Thermo resistant safety temperate anterior glass.
•Wall connection
•Silicone rubber seal gasket
•Electric cable mt 3 with shuko plug
WARNING
•Torque wrench setting of the racket adjustment screws ≥ 8 Nm.
•The appliance must be installed on non-flammable surfaces.
•It is suitable for installation above 2.5 meters in height.
•This appliance must be earthed.
•The minimum distance from the frontal glass and the surface to be heated must be at least 1,5 meters.
•The apparatus cannot be used without glass, in case of damage the glass must be replaced before use.
•The instrument must be installed beyond the normal accessibility volume.
•The apparatus does not have to be installed immediately under one electric socket.
•The apparatus must always be mounted in a perfect horizontal position.
•The apparatus has been developed for outdoor use.
•Do not use the appliance in a bathroom.
•Do not use the appliance in a bathroom.
The CE trademark indicates that the instrument has been manufactured according to European Community directives
regarding low tension and electromagnetic compatibility for lighting instruments
IMPORTANT
KEEP THE EXTERNAL SURFACE OF THE GLASS ALWAYS CLEAN IN ORDER TO AVOID LAMP OVERHEATING.
DISCONNECT FROM MAIN ELECTRICITY SUPPLY BEFORE CLEANING.
•Never use an extension cable with this appliance.
•Attention if you install WP 2000 in proximity of awnings, make sure that the heater does not go in contact with the
awnings.
•Connect WP 2000 to a 220-240 VOLTS singlephase power supply (according to the country).
•WP 2000 should always be earthed.
•It is important to ensure that the electricity supply is of adequate capacity for the electrical load required by the
appliance being installed.
•The heater must remain horizontal at all times.
•The lamp can be damaged if touched with bare hands, in this case it cannot be replaced under guarantee
•Do not cover or obstruct the heater while working.
•The replacement of the cable must be carried out by the manufacturer, by the authorized
after sale service or by a qualified electrician.
Power 1500/2000W
IP23 = Infrared Heater protected against rain
(cod. EH2000W1-EH2000W2)
7