EN
2.4
SETTING THE WEIGHING UNIT (CBCa Series only)
CBC,CBC-M scales are kilogram only scales but the CBCa scales are changeable from pounds to kilograms.
The scale will turn on displaying the last weighing unit selected, either kilograms or pounds. To change the
weighing unit press the [U. Wt./Units] key when the "Unit Weight" display shows zero. If necessary press
the [CE] key to clear the unit weight before changing.
2.5
PARTS COUNTING
To determine the number of items being weighed, should divided the net weight by the unit weight value. It
is necessary to know the average weight of the items to be counted which can be done by weighing a known
number of the items or by manually inputting a known unit weight using the keypad.
Weighing a sample to determine the Unit Weight
1) Zero the scale by pressing the [Zero] key if necessary. If a container is to be used, place the
container on the scale and tare as discussed earlier.
2) Place a known quantity of items on the scale. After the weight display is stable, enter the
quantity of items using the numeric keys followed by pressing the [Smpl] key.
3) The number of units will be displayed on the "Count" display and the computed average
weight will be shown on the "Unit Weight" display.
Or Entering a known Unit Weight
1)
Enter the value of the unit weight using the numeric keys followed by pressing the
[U. Wt./Units] key. The "Unit Weight" display will show the value as it was entered.
After calculate/enter the unit weight, you should add more items on the pan. As more items are added to the
scale, the weight and the quantity will increase. If a quantity which is smaller than the sample is placed, then
the scale will automatically enhance the Unit Weight by re-calculating it. To lock the Unit Weight and avoid re-
sampling, press [U. Wt./Units].
The scales will automatically update the unit weight when a sample less than the sample already on the
platform is added. A beep will be heard when the value is updated. It is wise to check the quantity is correct
when the unit weight has been updated automatically. This feature is turned off as soon as the number of
items added exceeds the count used as a sample.
2.6
CHECK COUNTING
Check counting is a procedure to cause an alarm to sound when the number of items counted on the
scale meets or exceeds a number stored in the memory.
1) Enter the numeric value to be stored using the numeric keys. Then press the [Pst] key to
store the value.
2) To clear the value from the memory and thereby turn off the check-weighing feature, enter
the value "0" and press [Pst].
2.7
ACCUMULATED TOTALS
© Adam Equipment Company 2013
3
3026610534, Revision A3, July 2013