6. Accessories
6.1 Combination detector and
laser remote control
With the A510S, use the RCR500 detector; with the A510G, use
the RCR500G. For grade rod or handheld applications. Also can
use the magnet mount to attach to metal studs for exterior curtain
wall alignment or to ceiling grids for acoustical ceiling leveling.
Magnet
Window for remote's
Level vial
LCD
screen
(front)
Detection
window
Turn to attach
clamp to
detector
Turn to tighten
or remove clamp
from rod
22
infrared signal
On-grade
alignment notch
LCD screen
(rear)
Bubble
vial to
plumb rod
9V battery
compartment
(follow polarity
indications inside)
Use a coin to unscrew
the battery cap
Detector mode
(red keys)
Choice of
sound level
Choice of
accuracy
On/Off
TROUBLESHOOTING
• Before using a detector, it is very important to set
the A510 in point mode. The receiver cannot
detect the beam in chalk line mode.
• If you cannot pick up the beam with the detector,
check how you are lined up with the laser. One of
the head protection supports on the laser may be
blocking the beam; move to the left or right to
receive the beam.
• The metal head protection can be removed from
the laser by pivoting the two security locks. This will
not affect the performance or the water or dust
resistance of the laser.
• If it's cold and there is no signal from the A510G,
allow some warm-up time (see Care and Handling
section).
Remote mode
• Lower
Keypad
Increase
rotation speed
Decrease
rotation speed
Start/Stop scanning mode
Calibration section of manual explains
function of secondary small symbols.
• Upper Keypad
Remote mode
Scanning mode
Move square
Aim scanning left
shot to the left
Move square
Aim scanning right
shot to the right
and
are used for calibration or
to set manual grade
Scanning mode
Increase
scanning angle
Decrease
scanning angle
23