EKKO
Unlock the actuator and move the gate leaf to the maximum desired opening. Secure the mechanical stop at the bottom of the gear motor.
N.B.: Check for the presence and tightness of the mechanical stops on both opening and closing. Should the gate leaf exceed a length of 1.6 metres it is
necessary to install the electrical lock.
Electrical wiring harnesses:
Open the cover of the compartment for the electrical wiring harness, take out the terminal block and do the wiring according to the diagram:
Terminal number
1
2
3
4
5
The electrical wiring between the control unit and the actuator must not exceed 15 metres
EN
Wire colour
White
Blue
Brown
Red
Black
Description
Encoder signal
Encoder power supply negative (GND)
Encoder power supply positive (+12 Vdc)
Motor power supply (opening)
Motor power supply (closing)