8 - Electrical connection of the gearmotor
The connecting cable to the control unit must have a sufficient curvature
to follow the movement of the gearmotor during operation. Unscrew the
cable grommet P, insert the cable through the gearmotor, and then lock
the cable grommet.
Make the connections on the terminal as indicated, respecting the con-
nections shown.
Description of electrical connection:
NB: the cable connecting the encoder to the control unit must not ex-
ceed 10 m in length. For lengths of wiring encoders exceeding 10 m but
not exceeding 15 m you must use a shielded cable.
9
P
1 OPEN
2 CLOSE
3 Encoder +
4 Encoder S
5 Encoder -
9 - User Manual
Manual unlocking operation: turn the cover 180°, insert the key and turn
90° anticlockwise, the gate leaf can be pushed manually, close the cover.
To re-lock the gate leaf, insert and turn the key clockwise.
- In the event of mains power failure, the back-up battery ensures the
operation of the automation system for a limited period. Should the
battery be flat or missing, manually unlock the motor, open the door,
insert the unlocking key and turn anticlockwise; it is advisable to move
the gate into the fully open position and reset unlocking by turning the
key clockwise and close the cover, which is to prevent any unwanted
movement of the gate (with the operator unlocked the gate leaf is free
to move, which could cause damage to property or persons). Once the
power supply is restored, the electronic board will charge the back-up
battery and the gate will return to normal operation after a command
pulse.
CAUTION: Unlock and reset with the gate stationary.
180°
If the automatic closing function is enabled (gate open and flashing lamp
on for 3 seconds), after the set time, the gate closes.
This function can be disabled by pressing the remote control button
before the gate opens completely.
If the sequential (step-step) function is enabled, when the button is
pressed the gate moves according to the open-stop-close cycle.
If the gate meets an obstacle on closing, and automatic closing is
active, the control unit makes 2 attempts at closing, after which it
remains open. It is necessary to remove the obstacle from its path
and control the gate with the remote control so that it closes at low
speed.
Maintenance and prevention:
- Periodically check the fixing screws, the integrity of the connecting
cables, the correct functioning of the safety systems (photocells and
sensitive edges), the robustness of the mechanical stops and the
soundness of the systems for supporting the gate leaf (hinges or bear-
ings). Every 2 years it is recommended to replace the batteries in the
remote control.
- When using the automation in cold weather (T < 0°), to easily rotate
the cover and enable the release, it is advisable to apply an anti-freeze
product. If the gate (and hinges) are already blocked by the ice, heat
the frozen parts before applying the antifreeze.
REACH (EU) Regulation no. 1907/2006 – Art.33.
The product may contain traces of lead.
E N