OUTPUTS
oFF
DISPLAY
ou 1
FLASHING LIGHT
Output (E1 - E2) is on intermittently
(2 Hz) during opening and closing
and during pause mode, if automatic
reclosing is active
ou 2
END OF CYCLE NON-ACTIVE SIGNAL
At the end of the operating cycle, the
control unit sends no signal

OPERATING LOGIC

oFF
DISPLAY
Lo 1
START/STOP LOGIC
The START/UP input controls the STEP or
AUTOMATIC operational cycle based on
the programmed operational logic.
The DOWN input is inactive
Lo 2
START INACTIVE WHILE OPENING
During opening, the START command
is ignored
Lo 3
STEP LOGIC
The start command activates an
OPEN-STOP-CLOSE-STOP-OPEN
operational cycle
Lo 4
DEAD MAN LOGIC INACTIVE
By simply using the start command, the
user can activate the automation device
in opening or closing.
The maximum duration of opening or
closing depends on the operating time
set
on
COURTESY LIGHT
The output (E1 - E2) is on and fixed during
opening, pause and closure. Having completed
the operating cycle, the light remains on for the
COURTESY LIGHT OFF DELAY time
END OF CYCLE ACTIVE SIGNAL
At the end of the operating cycle, the control
unit sends a signal to the WES sensors to activate
ENERGY SAVING mode
on
UP/DOWN LOGIC
The START/UP input always controls opening
and the DOWN input always controls closing,
independently of the operational logic
programmed.
UP + DOWN when pressed simultaneously is the
same as a STOP command
START ACTIVE WHILE OPENING
During opening, the START command interrupts
opening (no timer is set for automatic re-closure)
AUTOMATIC LOGIC
The start command activates an
OPEN-PAUSE-CLOSE-STOP operational cycle.
Closure starts automatically after the pause time
set
DEAD MAN LOGIC ACTIVE
The user must press and hold the start button
for the entire duration of the desired opening or
closing procedure.
The maximum duration of opening or closing
depends on the operating time set.
DEAD MAN logic may be implemented with
both Start/Stop and Up/Down logic.
The STOP command interrupts the operational
cycle, independently of the status of the control
inputs.
Hence, if the UP or DOWN button is pressed,
the action of STOP is to stop motion, and on its
release the motor DOES NOT MOVE UNTIL THE
UP or DOWN INPUT IS RELEASED AND PRESSED
ONCE MORE
PLEASE NOTE: when the Man-Present
function is enabled, radio-controlled
operation is disabled. To activate via radio,
Lo 7
on
set the parameter
=
- 18 -
dEF1
dEF2 dEF3 dEF4
oFF
on
on
on
oFF
on
oFF
oFF
dEF1
dEF2 dEF3 dEF4
oFF
on
on
on
on
on
on
on
oFF
oFF
oFF
oFF
oFF
oFF
on
oFF