Pump Installation - Hozelock Cyprio Cascade 700LV Instrucciones De Instalación Y De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
GB
The Hozelock Cyprio Cascade 700 Low
Voltage pump is designed for submersible use
only. The pump does not use oil or grease for
lubrication and can be used safely in ponds
containing fish or plants. The motor consists
of a sealed stator and water-cooled
permanent magnet rotor. All electrical
components are isolated from the water.
WARNING: SAFETY AND
ELECTRICAL CONNECTIONS.
1. WARNING - ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.
2. Position the transformer in a garage or
shed close to the mains voltage supply.
The transformer is not waterproof and
must be kept dry and under cover –
allowing for sufficient air circulation.
Do not position the transformer in direct
sunlight, eg.. greenhouse, window sills,
etc.. as high temperatures may cause
overheating.
3. Do not use the supply cable to lift the
pump, as this may cause damage. We
recommend fitting a lifting cord to the
handle eye on the top of the strainer cage
when the pump is installed in deep water.
.See Fig 1.
4. Do not operate or leave the pump in
freezing conditions.
5. Do not allow the pump to run dry.
6. Check that the voltage marked on the
pump corresponds to the low voltage
supply.
7. Do not operate this pump without the
strainer cage attached. Using the pump
without a strainer Cage may invalidate
your warranty.
8. The pump must only be connected to a
safety isolating transformer with a 24V
output, such as the one supplied with this
product.
9. Consult a qualified electrician or local
authority if in any doubt about wiring to
the mains supply.
ACCESSORY ASSEMBLY
Telescopic Stem Assembly.
Take the outer telescopic stem 'A' and slide
the inner stem 'B' into it, as shown. See Fig 2.
Bell Fountain.
1. Locate the Bell Support (D) to the Bell
Main Body (E) and push fully home.
2. Position the Bell (F) to the Body Assembly
and press into the central location.
See fig 3.

PUMP INSTALLATION

Position
Construct a solid and level platform on which
to place the pump. When using spray
fountains, the top of the platform should be
240-330mm (10-13") below the water surface.
When using the bell fountain, the top of the
platform should be 100mm (4") below the
water level.
A typical installation is shown for guidance in
fig 4.
Flow Control
The flow from the pump can be regulated to
meet your needs by rotating the flow
controller wheel (G) near the outlet of the
pump. See fig 5.
Fountain Only.
2
1. Place the pump next to the pond and
route the cable back to the mains supply.
2. Select the desired fountain accessory. The
2 and 3 tier fountainheads simply snap
onto the fountain stem (See Fig 6). The
fountain stem pushes onto the narrower
tube section of the telescopic fountain
stem (see Fig 6). Then place the pump in
the desired position. Note: Check that the
inner stem of the telescopic tube has not
been pushed inside the outer tube.
3. a). 3 tier fountain – Creates a wider and
attractive fountain spray.
b). 2 tier fountain – Creates a higher and
narrower display.
c). Bell fountain – Creates a decorative
water bell. Adjust the telescopic stem to
the required height and regulate the bell
by rotating the flow controller by the
outlet of pump.and by sliding the inner
bell in and out of the bell assembly.
4. The ball joint - See Fig 5 (H), fits onto the
pump outlet and the telescopic stem
pushes onto the top. This can then be used
to adjust the fountain angle so that it is
vertical.
Waterfall Only.
1. Fit a suitable length of hose 12.5mm bore
hose on to the hose adaptor. See Fig 5 (I)
2. Route the hose back to the waterfall.
TRANSFORMER INSTALLATION
Connect the pump to the transformer as
follows; (see Fig 8).
1. Plug the pump lead into the socket
provided on the flying lead for the
transformer. If an extension lead is
required, Hozelock Cyprio can provide
extension leads.
2. The cable supplied with this pump cannot
be replaced if the pump is damaged.
3. Plug the transformer into the socket. Take
care to position the cable so that it will
not place un-necessary pulling load on
transformer by leaving the flying lead
with slack cable.
4. The pump can now be switched on. Refer
to the "Pump Installation" section for
details on fountain height adjustment.
NOTE: This transformer is protected by a
single-shot thermal fuse. If this device
operates, the pump will stop working and
the transformer will have to be replaced. This
will only occur if the transformer overheats.
This can be caused by exposure to direct
sunlight. Ensure that the transformer
operates in a shaded area.
MAINTENANCE
The Hozelock Cyprio range of Cascade pumps
has been designed to allow fast and easy
maintenance. As with all pumps of its kind,
occasionally it will become necessary to clean
the Strainer Cage and Fountain Spray head
ring.
Always unplug or disconnect ALL appliances
in the pond from the electricity supply before
putting your hands in the water or starting
maintenance.
Fountain Head
1. Place a coin or similar in the slot and
gently lever off the fountain head.
2. Rinse in clean water and reassemble.
Strainer.
1. Remove the accessories from the pump
outlet.
2. Holding the pump in one hand, press the
release button (J) on the top of the pump
and open Strainer Cage. See Fig 5.
3. Slide the pump out of its location and
wash/rinse the Strainer Cage with clean
water. The hinges on the Strainer Cage
should also be washed clean at this time.
4. Reassemble the pump.
Rotor Assembly.
1. Remove the Strainer Cage as described
above.
2. Release the Pump Chamber, Fig 7 (K), by
rotating it until the two retaining tongues
are clear of the lugs on the Motor Body.
3. Gently pull the Pump Chamber squarely
away from the Motor Body.
4. Pull the Rotor Assembly out of the Motor
Body. See Fig 7 (L)
5. Wash out all of the components in clean
water. Do not use detergents or other
chemical cleaners.
6. Replace the Rotor Assembly into the
Motor Body and refit the Pump Chamber
and Strainer Cage.
ALL YEAR PUMP CARE
A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.
Once a week- Remove and clean the Strainer
Cage and Fountain Head in accordance with
the general maintenance notes. Depending
on pond water conditions, cleaning may be
required more frequently.
Once a year- Completely disassemble the
pump including the Rotor Assembly as
described in the general maintenance notes
and wash all components in clean, fresh
water. Replace worn or broken parts.
SPARE PARTS
Contact the Consumer Services Help line on
01844 292002
Item Numbers
700LV
1. Pump Chamber and Seal.
2. Rotor Assembly.
3. Strainer Cage.
4. Fountain Kit.
5. Transformer.
HOZELOCK CYPRIO 3 YEAR
GUARANTEE
If this pump, excluding the Rotor Assembly,
becomes unserviceable within 3 years of the
date of purchase it will be repaired or
replaced at our option free of charge, unless
in our opinion it has been damaged or
misused.
Liability is not accepted for damage due to
accident, improper installation or use.
Liability is limited to replacement of a faulty
pump. This guarantee is not transferable. It
does not affect your statutory rights.
To obtain the benefits of the guarantee,
firstly contact Hozelock Cyprio Consumer
Services who may request that the pump is
sent along with proof of purchase directly to
the address below.
DAMAGE CAUSED BY RUNNING THE PUMP
DRY OR BY FROST INVALIDATES THE
GUARANTEE.
Hozelock Cyprio,
Haddenham,
Aylesbury,
Bucks. HP17 8JD
England.
Tel: +44 (0) 1844 292002
Fax: +44 (0) 1844 291820
Z13248
3419
Z13225
3426
Z13190

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3052

Tabla de contenido