Descargar Imprimir esta página

Maintenance - MGF S-GH017 Manual De Instrucciones De Funcionamiento Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DO NOT FORGET to close the valve again when the tank is empty, particularly if the
1. Check the oil level
Before using the compressor, check the oil level by viewing the oil sight glass ( Fig. 6 ).
17 an30 Lt versions are always supplied with oil inside. 50 Lt. Versions are supplied without
oil inside.
If necessary top up using synthetic MGF oil only available from your MGF dealer. To add oil
remove the aspiration filter ( Fig. 1-B and Fig. 2-B ) and add enough oil until the level
reaches the middle of the oil sight glass. Be careful when replacing the filler plug not to
cross-thread it.
Never exceed the maximum oil level shown on the label, this will compromise the
MGF Silent compressors operating
instruction manual
IMPORTANT:
compressor may not be used for some time

MAINTENANCE

DAILY
Fig. 6
IMPORTANT
correct compressor running.
10

Publicidad

loading