Position the Bell (G) to the Body
Assembly and press into the central
location.
3.2 2 and 3 tier fountain display assembly
(Fig 2-H).
The plastic discs that create the 2 and 3
tier water displays simply snap onto the
fountain stem.
4.0 INSTALLATION
4.1 Place the unit next to the pond and
route the cable back to the mains
transformer supply. Ensure that you
allow for enough cable for positioning
the product in the desired location in
the pond.
Fountain operation
4.2 Position - Construct a solid and level
platform on which to place the
EasyClear™. The platform should be
greater than 300 mm (12") below the
water level. For depths between 300mm
and 600mm use the fountain stem
extension segments (Fig 11-7), which
simply screw together, to allow the
fountain to be above the water level.
For general installation see Fig 3.
PLEASE NOTE: The product has a water
by-pass to control water flow rates
which means a quantity of water will
always come out of the product just
below the flow control. This is normal in
operation.
4.3 Position the unit in the pond. The 2 and
3 tier fountainheads simply snap onto
the fountain stem (Fig 2). The fountain
angle can be adjusted to be vertical
using the ball joint (Fig 4). The tightness
of the ball joint can be adjusted (Fig 4-L)
4.4 If required, the 2-Tier Fountainhead can
be used to achieve an alternative and
higher display pattern than the 3-Tier.
4.5 The fountain height can be adjusted to
suit your needs by rotating the Fountain
Flow Adjuster. (Fig 5-M)
4.6 The Bell Fountain creates a decorative
waterbell. The size of the bell can be
adjusted to suit your needs by rotating
the Fountain Flow Adjuster (Fig 5-M).
UVC operation
4.7 The UVC will automatically switch on
once the unit has been connected to the
electricity supply.
4.8 The UVC lamp can be checked for
operation by looking for a bluish glow
from ball joint outlet (Fig 2-D).
4.9 See Maintenance section 6.4 for Lamp
replacement.
5.0 MAINTENANCE
The Hozelock Cyprio EasyClear™ has been
designed to allow fast and easy
maintenance. As with all pond equipment,
occasionally it will become necessary to
clean or replace parts. Refer to section 1 & 2
before attempting any maintenance.
ALWAYS UNPLUG OR DISCONNECT ALL
APPLIANCES IN THE POND FROM THE
ELECTRICITY SUPPLY BEFORE PUTTING YOUR
HANDS IN THE WATER OR STARTING
MAINTENANCE.
5.1 Fountain Head (Fig 2-J)
a - Place a coin or similar in the slot and
gently lever off the fountain head.
b - Rinse in clean water and reassemble.
5.2 Foam
2
a - Release the Foam Cover by pushing
the two grey buttons (Fig 6-N) and lift
the cover (Fig 7-O).
b - Lift the Foam with the Foam Support
(Fig 8-P). Note :- If the unit is out of the
pond for more than 20 minutes the
biological filter action may stop
working.
c - Lift the Foam and stone bag off the
Foam Support, rinse all parts in a bucket
of pond water and reassemble.
d - The Foam Cover and Base should also
be rinsed.
e - Reassemble the Filter.
5.3 Quartz Tube
a - Remove the bayonet locking screw
(Fig 1-A), twist and lift the bayonet tube
(Fig 1-B).
b - Clean the Quartz Tube. Especially in
hard water areas, the quartz tube may
become covered in limescale, which will
reduce efficiency. Clean the tube with a
soft cloth and a gentle de-scaler, rinse in
water before refitting.
5.4 Lamp replacement
Change the lamp at the start of the new
season. Even though the lamp still glows
it may not be giving out any useful UV
radiation.
a - How well the EasyClear™ performs is
related to the strength of the UV
radiation produced. This will slowly
decline from the day your lamp is
switched on. The UVC lamp has an
effective life of 12 months. You need to
change the lamp when there is a
significant reduction in water clarity.
Make sure this is due to an expired lamp
and not a badly maintained filter or a
dirty/limescaled quartz sleeve. Both can
greatly reduce UV transmission into the
water.
b - Remove the Bayonet Tube assembly -
ref to section 5.3.
c - Remove the quartz tube, rotating
the plastic moulding anticlockwise
and lifting up and away (Fig 9-Q).
d - With the lamp now accessible pull
it out of the holder (Fig 9-R) and
push in a new lamp.
e - Reassemble the filter and switch back
on.
5.5 Biological Filter
Normally, there is no need to remove
the bio-media as any cleaning may kill
the colonies of bacteria that make toxic
waste harmless.
a - Remove the foam – ref to section 5.2.
b - Remove the 4 fixing screws (Fig 10-T)
and lift the base clear.
c - The 6 pieces of Biomedia (3 either
side of the pump)can be removed for
cleaning.
d - Wash in pond water.
e - Reassemble the filter and restart.
5.6 Rotor Assembly
a - Remove the foam – ref to section 5.2.
b - Remove the 4 fixing screws (Fig 10-T)
and lift the base & biomedia clear.
c - Remove the 2 fixing screws (Fig 10-U)
and lift the Pump Assembly clear.
d - Twist the Pump Chamber anti-
clockwise (Fig 10-V) and lift clear. The
rotor can now be pulled out for cleaning
or replacement ( Fig 10-W).
e - Reassemble the pump and 2 fixing
screws (Fig 10-U).
f - Reroute the cable (Fig 10-X).
g - Reassemble the filter, and restart.
6.0 ALL YEAR PUMP CARE
A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.
Once a week- Remove the outer casing and
Fountain Head in accordance with the
general maintenance notes. Depending on
pond water conditions, cleaning may be
required more frequently.
Once a year- Completely disassemble the
unit including the Rotor Assembly as
described in the general maintenance notes,
refer to sections 5.1 - 5.6, and wash all
components in clean, fresh water. Replace
worn or broken parts.
7.0 SPARE PARTS (refer to Fig 11).
Contact the Consumer Services Helpline on
0870 850 1959.
8.0 HOZELOCK CYPRIO 2 YEAR GUARANTEE
Item Numbers
1. Foam.
2. UV Lamp.
3. Quartz Tube.
4. Pump chamber & O-Ring.
5. Pump rotor.
6. Fountain and extension
segment bagged set.
7. Foam cover.
8. Foam support.
9. Transformer
If this unit, excluding the Rotor Assembly,
Filter Foam & UV Lamp becomes
unserviceable within 2 years of the date of
purchase it will be repaired or replaced at
our option free of charge, unless in our
opinion it has been damaged or misused.
Liability is not accepted for damage due to
accident, improper installation or use.
Liability is limited to replacement of a faulty
unit. This guarantee is not transferable. It
does not affect your statutory rights.
To obtain the benefits of the guarantee,
firstly contact Hozelock Cyprio Consumer
Services who may request that the filter is
sent along with proof of purchase directly to
the address provided.
DAMAGE CAUSED BY RUNNING THE FILTER
DRY OR BY FROST INVALIDATES THE
GUARANTEE.
9.0 WINTER STORAGE
When not in use, the unit should be
removed, thoroughly washed and cleaned,
dried and stored in a dry frost protected
area. Always store the unit with the foam
and foam cover off to ensure adequate
ventilation and drying. Refer to maturation
section when restarting the unit.
10.0 - FISH STOCKING RATE AND DENSITY
Under normal conditions, the EasyClear™
will support up to 72cm of fish. Introduce
fish slowly over the first few weeks, up to
20% of the maximum recommended level,
increasing to 50% after six months. The
balance will allow for fish growth.
1406
1519
1526
Z13247
3418
Z31785
Z13228
Z13229
Z13195