3. OPERATION
PLEASE READ CAREFULLY BEFORE USING
Suitable for 12V Normal Lead Acid, Sealed, Leisure or Gel Batteries between 14-160Ah.
1. Charging your battery
It is essential to disconnect the battery from the car. This will avoid possible damage to the alternator. To
avoid damage to the bodywork from possible spillage, remove the battery completely from the vehicle. It is
advisable to use gloves when handling the battery, as there is a high possibility of corrosive acid being on
the outside of the battery.
2. Preparing the battery
Firstly remove the caps from each cell and check that the level of the liquid is sufficient in each cell.
If it is below the recommended level, top up with de-ionized or distilled water.
Note: Under no circumstances should tap water be used.
The cell caps should not be replaced until charging is complete. This allows any gases formed during
charging to escape. It is inevitable that some minor escape of acid will occur during charging.
For permanently sealed battery, it is not necessary to carry out the above checks.
3. Reverse Polarity
If the DC battery clamps are connected improperly to the battery terminals, the reverse polarity LED will
indicate the reversed polarity. The battery charger's warning buzzer will also sound. If this occurs simply
disconnect the battery charger from the AC power. Connect the DC clamps correctly to the battery
terminals. Reconnect the charger to the AC power.
4. Charging
The battery charger is now in the standby operating mode and the "SLOW", "STD" and "POWER" LEDs are
illuminated. This is the standard charging mode and as soon as the START button is pressed, the charger
switches immediately into the 12V, 3A RMS, STANDARD battery charging mode.
If you require an alternative selection, proceed as follows:
Step 1
Select the desired charge current: "SLOW" (2 A DC) or "FAST" (7.5A DC).
Step 2
Select the battery type: "STD" or "RECOND". STD indicates a common lead acid battery, calcium battery,
Maintenance Free battery, e.g. Gel Cell, VRLA, AGM & etc. RECOND stands for Deep Cycle batteries.
Step 3
Press the "START" button to begin charging the battery.
Battery Fault a few seconds after switching on to the operating mode, the LED indicator "FAULT" will illuminate
if the following occurs:
A- Low battery voltage - < 3 V
B- High battery voltage - > 15 V (12 V battery)
C- Battery short circuit or battery cell short circuit
Under these conditions, the battery charger will stop charging. In the event of A, B or C, the battery may be
defective and we advise you to consult your nearest battery service centre.
When the LED "FULL" illuminates, the battery is completely charged. The battery charger now switches to the
Float mode and doesn't require your attention until the next time it is used. The INVERCAR 750 battery charger
will automatically maintain your battery.