Current Measurement; Voltage Measurement - koban KPA 01 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Current Measurement

1. For AC current move rotary switch to A~ position; for DC current move
rotary switch to A
2. Open the clamp head by pressing the trigger and inserting the conductor
to be measured.
3. When measuring AC current, the main display shows the measured
current value while the secondary display shows the frequency of the
measured current
Note:
1. Measuring two or more wires together will cause false readings.
2. The wire being measured should be centered within the clamp.
3. "
" indicates the maximum input AC/DC current is 600 A.
4. For higher accuracy, when measuring DC current if Display shows non
zero, press "ZERO/REL" button to reset the reading to zero.

Voltage Measurement

1. Insert the black test leads into "COM" input and red test lead into "INPUT"
input, choose proper range.
2. Move rotary switch to V
Press "FUNC" to switch to DC voltage.
3. For mV measurement, press "RANGE" button until in mV range.
4. Connect test leads to voltage source or load.
5. Voltage measurement will be shown on main display.
Note:
When measuring low voltage sources, the reading will fluctuate on the
display when the test leads are not connected to the circuit. This is normal
due to the high sensitivity of the Meter. The Meter will display correct reading
once the leads are connected to the circuit.
Frequency and Duty Cycle
1. Insert the black test leads into "COM" input and red test lead into "INPUT"
input
2. Turn rotary switch to "Hz" position.
3. Connect test leads to the voltage source or between loads.
www.grupotemper.com
position.
position. AC voltage is default measurement.
KPA 01
Digital clamp multimeter
Instructions manual |
33

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido