DOSATRON Venturi
DOSAGE
In the DOSING function (water + additive), the concentrated detergent or
disinfectant is dosed and mixed with the water passing through the unit.
The concentration is adjusted by changing the colour coded dosing jet.
How to change the jet
Unscrew
the nut
Dosing jets
COLOURS
MAX. INJECTED
CHEMICAL L/h
RED
2,8
ORANGE
3,42
BLACK
4,73
LIGHT GREEN
8,02
YELLOW
10,59
BROWN
15
DARK GREEN
23,2
WHITE
36,8
BLUE
52
VIOLET
75,53
GREY
107
BEIGE
111,7
NO JET
114
This document does not form a contractual engagement and is for information only.
The company DOSATRON INTERNATIONAL reserves the right to change its products at any time
MAX.
DOSAGE %
Dosing rate values measured under the
1
following test conditions :
Product injected
1,25
1,7
Caution !
2,9
The concentrate's viscosity and its specific
3,75
gravity exert a direct influence upon the
5,3
dosage.
8,2
All venturi systems necessitate a study of the
11,5
installation and the creation of constant
16,8
operating conditions (flow, pressure, product
24,8
viscosity) to obtain reproduceability.
40,7
43,2
43,6
DOSATRON VENTURI - Page 5
jet
Pull out the jet
and change it.
Water
ENGLISH