Allmatic BIOS2 Guía Para La Instalación página 17

Cuadro de mando programable para cancelas a batiente
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

For a correct functioning of the system, it is absolutely indispensable the use of mechanical stops in opening and closing.
5.2 Advanced settings of the wings stroke (parameter LsI
Connect to the MOTOR 1 output the wing which beats.Install an aventual electrical lock on this wing. MOTOR 1 is always activated first during opening
phase and in second during closing phase. In this procedure it is necessary to provide also the positions where the slowing downs begin with a step by
step command (SS).
Unlock the motors, move the wings in the middle of the
1
stroke and relock the motors.
Press and keep pressed the buttons UP[+] e MENU
for at least 5 seconds.
2
When the wing 1 reaches the opening mechanical
stop give a step by step command (SS)
3
When the wing 2 reaches the opening mechanical stop
4
give a step by step command (SS)
When the wing 2 reaches the desired
5
beginning of slowing down give a step by step
command (SS)
When the wing 2 reaches the closing mechanical stop
6
give a step by step command (SS)
When the wing 1 reaches the desired
7
beginning of slowing down give a step by step
command (SS)
When the wing 1 reaches the closing mechanical stop
8
give a step by step command (SS)
When the wing 1 reaches the desired
9
beginning of slowing down give a step by step
command (SS)
When the wing 1 reaches the the opening mechanical
10
stop give a step by step command (SS)
When the wing 2 reaches the desired
11
beginning of slowing down give a step by step
command (SS)
When the wing 2 reaches the the opening mechanical
stop give a step by step command (SS)
12
Warning: in case of intervention of a safety device, the learning is stopped and will appear on the display the written
Press Step by Step key to start again the learning from the 2
6-1622189
rev.7
02/09/2019
LsI = P P P P )
LsI
LsI
The wing 1 moves in opening.
If the wing moves in closing press the button
DOWN to stop and reverse the direction of
movement and give a step by step command
(SS) to resume the procedure
The wing 1 stops and the wing 2 moves in
opening.
If the wing moves in closing press the button
DOWN to stop and reverse the direction of
movement and give a step by step command
(SS) to resume the procedure
Wing 2 stops, after 2 seconds the wing 2 moves
in closing
The wing 2 begins the slowing down
position of
Wing 2 stops, after 2 seconds the wing 1 moves
in closing
The wing 1 begins the slowing down
position of
Wing 1 stops, after 2 seconds the wing 1 moves
in opening
The wing 1 begins the slowing down
position of
Wing 1 stops, after 2 seconds the wing 2 moves
in opening
The wing 2 begins the slowing down
position of
Wing 2 stops, the gate closes with the slowing
downs set during the learning phase and the
delay between the wings set in the menu. When
the gate is closed the learning phase is ended.
nd
point.
ITA
ENG
FRA
ESP
DEU
POR
5 / 12

Publicidad