2 Product Description
2 Product Description
2.1 Designated Use
2.2 Use contrary to the designated use
2.3 Technical Data
Welding
Transport and storage
Relative humidity
Tab. 1
Ambient temperature
Type of voltage
Polarity of the electrode
Wire types
Type of use
Voltage rating
Protection type of the machine-side connections
Shielding gas
Tab. 2
General torch data according to EN 60 974-7
Type
Type of
cooling
ROBO...
VTS 290
liquid
VTS 500TS
liquid
Tab. 3
Product-specific torch data as laid out in EN 60974-7
1For pulse arcs, the load data are reduced by up to 35%.
EN - 4
The VTS torch system must be used for robot and automatic application. Any
use beyond that is prohibited. Designated use also includes the observance of
the prescribed operating, maintenance and servicing instructions.
Any use other than that described under "Designated Use" is considered
contrary to the designated use. Unauthorized conversions or power increase
modifications are not allowed.
1
Load
ED
Wire ø
CO
M21
2
(A)
(A)
(%)
(mm)
290 100
0.8 - 1.2 10 - 20
500 100
0.8 - 1.6 10 - 20
- 10 °C to + 40 °C
- 10 °C to + 55 °C
up to 90 % at 20 °C
DC direct voltage
positive
commercially available round wires
automatic
141 V peak value
IP2X (EN 60 529)
Mixed gas M21 (DIN EN ISI 14175)
Gas flow
Max.
flow
temp.
(l/min)
(°C)
50°
VTS torch system
Cooling data
Min.
Flow pressure
flow
min.
max.
(l/min) (bar)
(bar)
1.2
1.5
3.5
1.2