1 Before starting the procedures described below, wash your
hands with antibacterial soap.
2 Prepare 2 gallons of Stera-Sheen sanitizing solution
according to the manufacturer's instructions.
3 Immerse all parts to be sanitized in the solution for the time
indicated by the product manufacturer.
4 Allow the sanitized parts to air dry on a clean surface.
5 Dry the external parts of the dispenser without using
abrasive cloths.
6. 4. 4 ASSEMBLY
NOTE: Total Blend sanitary lubricant, or equivalent must be
used when lubrication of parts is specified. Total Blend can
be used to lubricate parts and also as a spline lubricant. Do
not use more than one packet of Total Blend per freezing
cylinder.
NOTE: The United States Department of Agriculture and the
Food and Drug Administration require that lubricants used
on food processing equipment be certified for this use. Use
lubricants only in accordance with the manufacturer's
instructions.
1 Install the drip tray.
IMPORTANT
Lubricate the spigot piston, the auger seal and the front
of the auger in the points indicated in figure using only
Total Blend or other food grade sanitary lubricant.
2 Install the auger coupling onto the auger and insert it into
the freezing cylinder. Rotate the auger so that the coupling
engages the drive shaft.
3 Assemble the spigot assembly by first inserting the spigot
piston into the front door. Then install the handle onto the door
and secure it with the pin. Refer to Figure 20.
4 Place the front door assembly onto the studs and secure
with the knobs, tightening them carefully.
5 Reassemble the front panel. (see figure 26)
6 Assemble the hopper auger taking care to insert the ends in
the grooves in the hopper.(see figure 27)

6. 4. 5 IN-PLACE SANITIZATION

The sanitizing of the assembled machine prior to operation
should be performed in addition to the sanitizing of the disas-
sembled machine described herein above, and never instead of
it.
1 Prepare 2 gallons of sanitizing solution according to the
manufacturer's instructions (Stera-Sheen green label).
2 Pour the solution into the hopper.
3 Using a suitable brush, wipe the solution onto all the parts
above the level of the solution including the underside of the
hopper cover.
4 Install the cover and operate the machine for approximately
5 minutes.
5 Drain the sanitizing solution from the bowls through the
spigots and then dispose of it.
6 Place a container under the spigot and rinse the machine
with mix to flush out any remaining sanitizing solution.
7 MAINTENANCE
1 Every day: check the machine and make sure there are no
leaks from the spigot assembly seal. If you notice a leak, first
check that the components have been assembled correctly,
then make sure the seal is not worn or damaged, in which case
replace it with an original spare part from the manufacturer.