Battery Removal - NSS CHARGER 2022 ABLT Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

 Lubricate all moving parts as required with a small
amount of grease.
 DO NOT lubricate the Gas Spring shaft, it does not
require lubrication as it is self lubricating.
Every 6 Months
(Every 600 Hours)
Call your Authorized NSS Distributor / Service
Station to have the following services performed.
Verify that all daily, weekly, monthly and quarterly
maintenance has been performed.
Inspect Pad Motor carbon brushes for wear.
 Using compressed air, blow the accumulated carbon
brush dust out of the motor.
 Remove the motor cover and guard to expose the
carbon brushes.
 Replace carbon brush when they measure ½" [13mm]
or less in length.
 Failure to replace carbon brushes will cause poor
machine performance and possible motor damage.
Check the condition of the batteries.
 A battery may be checked using a Hydrometer to
check the specific gravity (strength) of the acid in
each cell. Variations in readings occur due to the
chemical reaction taking place during use.
 Always check the specific gravity when the battery is
fully charged.
 When the batteries are fully charged, the specific
gravity should be between 1.265 and 1.300.
 Consult your local distributor and replace batteries as
needed.

Battery Removal:

 Turn off all switches. Disconnect battery pack from
the machine.
 Remove the battery cables from the batteries.
CAUTION: Do not short across terminals with a wrench.
 Lift batteries straight up one at a time and out of the
machine.
Battery Installation:
 Turn off all switches.
 ALWAYS wear eye protection, rubber gloves and
protective clothing to avoid contact with battery acid
when installing batteries. See Battery Warnings on
page 3.
 Batteries are heavy – ALWAYS use two people to
install batteries into machine.
 Refer to wiring diagram located on the underside of
the cover. Align batteries in compartment the same
as the old batteries or as shown on diagram.
 Install battery cables the same as they were on the
old batteries or as shown on wiring diagram located
on the underside of the cover.
 NSS recommends replacing the battery cables when
replacing batteries.
 Tighten bolts and hex nuts with a wrench.
 Install terminal boots over terminals to complete
installation.
CAUTION: Do not short across terminals with a wrench.
CAUTION: Loose or improper battery connections will
cause battery or machine damage and possible
personal injury.

Publicidad

Tabla de contenido
loading

Tabla de contenido