Controller Components
3 - Control Dial Positions
SEASON ADJUST
stations in a program to be simultaneously
increased or decreased in 10% increments.
SPECIAL FUNCTIONS
timing features for pump operation and well recovery
delay feature.
– Enables all watering operations
RAIN DELAY
to be delayed from 1 to 7 days.
– Shuts off and prevents all automatic and
OFF
manual watering activity.
4 - Program Select Switch – Three-position slide
switch used to select watering program A, B or C
during the programming procedures and manual
operation.
5 - Rain Sensor Circuit Control Switch – Enables the
Rain Sensor circuit to be bypassed as necessary.
6 - Rain Sensor Configuration Switch – Configures
the controller for operation with a Normally-open or
a Normally-closed rain sensor.
7 - Rain Sensor Connection Terminals – Snap-in wire
connectors for direct connection of a Rain Sensor.
8 - Valve Common Connection Terminal – Snap-in
wire connector for the valve common wire.
9-
Pump/Master Valve Connection Terminal –
Snap-in wire connector for connection of a pump
start relay or master valve 24 VAC power wire.
4
– Enables the station time of all
– Provides optional control and
10 - Transformer Connection Terminals – Snap-in
connectors for transformer wires.
11 - 2-Station Expansion Module – Each 2-station
expansion module provides connections for two
irrigation control valves. Up to 6 modules for a total
of 12 stations can be installed. Provides 1.3 Kv
surge protection on each output.
12 - Remote Control Receiver Jack – Modular jack
provided for the connection of an optional
Toro Remote Control receiver cable.
(Installation and operating instructions are provided
with the Toro Remote Control system.)
13 - External Transformer – A Plug-in transformer sup-
plies 24 VAC power for the indoor controller models.
14 - Internal Transformer – A built-in transformer supplies
24 VAC power to the outdoor controller models.
15 - Input Power Terminal Block – Connection termi-
nals for AC power wires.
16 - High-surge 2-station Expansion Module – Each
2-station expansion module provides connections
for two irrigation control valves. Up to 6 modules for
a total of 12 stations can be installed. Provides
6.0 Kv surge protection on each output.
Note: This module can only be used in high-surge
outdoor controller models.