Technical Data; Geared Motor Installation; Electrical Connection - DITEC Arc B Manual Para La Instalacion Y La Manutencion

Automatización para cancelas batientes
Ocultar thumbs Ver también para Arc B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
1.

TECHNICAL DATA

Power supply
Absorption
Torque
Run time
Service class
Min. number of consecutive cycles
Intermittence
Temperature
Degree of protection.
Control panel
Application:
mm = door wing width
kg = door wing weight
Recommended dimensions
Limit dimensions
2.
REFERENCE TO ILLUSTRATION and AC-
CESSORIES
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Flashing light
[3]
Key selector
[4]
Connect power supply to a type-approved omnipolar-
switch with a contact opening gap of no less that
3 mm (not supplied by us) protected against accidental
and unauthorized activation. Connection to supply mains
must be carried out in an independent raceway separate
from control connections and safety device connections.
[5]
Control panel
[6]
Arc B geared motor
[7]
Photocells
2.2 Geared motor references
[8]
Gate attachment bracket
[9]
Housing
[10] Attachment plate
[11] Drilling templates for release key
[12] Release shaft
2.3 Accessories
Arc FB (*)
Adjustable stop
Arc PL (*)
Plate for front attachment of geared motor
Box FC1
Limit switch
(*) Two TCEI M8x130 screws, don't supply by us, are necessary in
order to use the ArcFB and ArcPL accessories at the same time.
3.
INSTALLATION
Unless otherwise specified, all measurements are expressed
in millimetres.
ARC B
230 V~ / 50 Hz
1,2 A
300 Nm
22 s/90°
3 - FREQUENT
20
S2 = 15 min, S3 = 25%
-20° C / +55° C
IP54
E2 / Logic A21-A22
500 kg
400 kg
300 kg
200 kg
100 kg
1
3.1 Preliminary checks
Check that the structure is sufficiently sturdy and that the hinge
pivots are properly lubricated. Provide an opening and closing
stop.

3.2 Geared motor installation

-
Remove the geared motor from its package. Attention:
Cover [9] is not secured.
-
Disassemble the reduction gear from the fixing plate [10].
-
Attach plate to gate column according to measurements
specified in figures 6 and 7, depending on type of installation.
-
Assemble the geared motor on the fixing plate following
fig. 8 for the fitting onto the left pier, inside view, and fig.
9 for fitting onto the right pier, inside view.
-
Release the geared motor (see operating instruction).
-
Attach articulated arms and gate attachment bracket as
shown in figures 10 and 11 and according to measure-
ments specified in figures 6 and 7.
Attention: bring the leaf to the stop line, align the arms
by means of holes [D] as shown in the detail in fig. 10.
The articulations on the arms should be lubricated and
the screws tightened in such a way as not to block arm
movement.
-
Drill the cover Ø 14 near release shaft [12] (there are two
drilling templates [11] in side the cover) and insert the
rubber plug (supplied). Attach the cover to the geared
motor.
4.

ELECTRICAL CONNECTION

-
ARC B geared motor electrical wiring and starting are
shown in fig. 12 and in the installation manual of Control
Panel E2, Logic A21 and LogicA22. To reverse the direc-
tion of rotation, exchange the motor phases (U with V
and/or X with Y).
-
ARC 1BH geared motor electrical wiring and starting
are shown in fig. 15 (1 wing) or in fig. 16 (2 wings) and
in the installation manual of Control Panel LogicC22. To
reverse the direction of rotation, exchange the motor
phases (36 with 34 and/or 33 with 31).
9
ARC 1BH
24 V=
12 A
300 Nm
15÷30 S/90°
4 - HEAVY DUTY
>50
S2 = 30 min, S3 = 50%
-20° C / +55° C
IP54
Logic C22
2
3
4
5
m
ARC BH
24 V=
3 A
150 Nm
15÷18 s/90°
4 - HEAVY DUTY
>50
S2 = 30 min, S3 = 50%
-20° C / +55° C
IP54
D2H / Logic C22-C22S
500 kg
400 kg
300 kg
200 kg
100 kg
1
2
3
4
ARC - IP1725
GB
5
m

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Arc 1bhArc bh

Tabla de contenido