Electrical Connections (Soakers With Chromatherapy Only); Chromatherapy Light Installation - Jacuzzi SOAKER Serie Instrucciones Para La Instalación Y El Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Soaker™ Bath Series
Subfloor
Prepare the subfloor for the drain and ensure that the area is level.
The drain/overflow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical
1
Specifications Manual that corresponds with your bathtub.
Make appropriate cuts to the subfloor to accommodate the drain.
2
Jacuzzi's Tru-Level™ base is a standard feature on all bathtubs. If the subfloor is level and a continuous surface,
3
no other preparation is necessary. Proceed to the "Installation" section.
If the subfloor is not level, you must level the entire surface prior to installing the bathtub. The materials used
4
will insure that the bathtub is supported from the bottom. These materials include: leveling compound, mortar,
plaster or minimal expansion structural foam (having a density of a minimum 5lbs/cubic foot). The bathtub must
remain level in order for it to drain properly and must make contact with the leveling material. Both sides of a joint
or splice of subfloor should be level to each other.

Electrical Connections (Soakers with Chromatherapy Only)

Risk of electric shock. Connect only to a circuit
protected by a GFCI.
When using electrical products, basic precautions
should always be followed:
Always follow local building and electrical codes.
For soakers with chromatherapy, grounding is
required. The unit should be installed and
grounded by a qualified electrician.
A 120V, 15A, GFCI protected circuit is required. Install a
duplex outlet to the wall stud underneath the bathtub, at
least 4˝ (101mm) above the floor. The duplex outlet is not
supplied.

Chromatherapy Light Installation

Your bathtub comes with two lights, cables, and control
box (pre-installed). The control panel requires installation
in a location selected by the installer.
Plan the location of the control panel. A possible
1
configuration is shown at right (Figure 2).
The panel cannot be immersed in the bathtub
water. Select a location at least 1˝ above the level
of the overflow drain.
The control panel must be installed on a flat surface
at least 3˝ wide x 2˝ tall. You may mount on any flat
surface on the bathtub shell, bathtub surround or
on the adjacent wall.
The control cable has a length of 10'. If you plan to
remote-mount the control panel (not on the bathtub
deck), the control panel cannot be located more
than 10' from the control box.
Installation and Operation
Reset
Test
Chromatherapy
Lights
Figure 2 - Possible Configuration
www.jacuzzi.com
Control Panel
Page 7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pure air serie

Tabla de contenido