BRS LCi PLC
5.2 Injection jig
1
2
3
1
Anti-spatter fluid adjusting screw
2
Flow control valve for adjusting the anti-spatter fluid
Fig. 5
Reamer injection jig
WARNING

Risk of crushing

Limbs can be drawn in and crushed by moving parts (reamer, clamping unit).
• Keep your hands away from moving parts.
WARNING
Damage to the eyes
When injecting the anti-spatter fluid, spray mist can form that can damage the eyes.
• Wear safety goggles.
• Only adjust the anti-spatter fluid by opening the solenoid valve Y4.
1 The welding torch moves into the cleaning position
2 The control box (HAN 3AQ5: PIN5=24 V) queries the ready signal
3 Once the ready signal is available, the start signal can be set (HAN 3AQ5: PIN5=24V- XS1)
4 Once cleaning is complete, the ready signal is sent from the control box to the robot
5 Injection via 24 V signal on HAN 3AQ5: PIN2
The injection period is specified by the robot.
The anti-spatter fluid volume can be set as required using an adjusting screw (1) on the Venturi valve (3).
BAL.0424.0 • 2019-04-23
4
5
3
Venturi valve
4
Transmitter disc
5 Functional description
5
5/2 directional valve for
injection unit (on/off)
EN - 11