8 Putting out of operation

8 Putting out of operation
NOTICE
• When decommissioning the system, ensure that the procedures for switching off the welding components are
observed.
1 Switch off the robot control.

9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed, or worn parts.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
9.1 Maintenance intervals
NOTICE
• The specified maintenance intervals are guidance values and refer to single-shift operation.
When using arc welding equipment, always observe the provisions of EN 60974-4 Inspection and testing, as well as any
national laws and regulations.
Check the following:
Weekly
1 Check the condition of the reamer.
2 Clean the clamping unit and the reamer.
3 Grease the DAV cutter guide after approx. 20,000 cuts.
Tab. 16
Maintenance intervals
EN - 22
Monthly
Monthly basic cleaning is recommended, and necessary in
the case of extreme working conditions.
BRS LCi PLC
BAL.0424.0 • 2019-04-23