5 Functional description
5.3 Sub-assembly: wire cutting device (DAV—externally controlled)
NOTICE
• The DAV is not controlled via the control box!
• It is directly controlled by the 5/2 directional valve on e. g. a robot.
1
9
1
Short stroke cylinder
2
Cover with lubricating nipple
3
Bracket
Fig. 6
Wire cutting device (DAV) sub-assembly
The valve for the DAV is only provided if specifically ordered and must be installed by the operator.
It can be attached to the injection valve island (5).
5.4 Optional assemblies/accessories
Prism
Reamer
Maintenance unit
5/2 directional
valve
Tab. 15
Options/accessories
EN - 12
2
3
4
8
7
6
4
Jaws
5
Injection valve block with empty space
6
Cutter
Anti-twist fastening with an M5x16 cylinder head screw in the clamping device.
The reamer dimensions are determined based on the gas nozzle and torch geometry for an
immersion depth of up to 50 mm. The reamer can be provided for all standard WH and robot
torch versions with nominal diameters from 13 mm to 19 mm.
ID 830.0075
Consists of a filter regulator and oiler.
The maintenance unit removes solid particles from the compressed air and adds atomized oil for
lubricating the pneumatically driven components.
ID 831.0729
The valve for the DAV is only provided if specifically ordered and must be installed by the
operator.
It can be attached to the injection valve island (5).
BRS LCi PLC
5
7
Pressure spring
8
Slide
9
Housing
BAL.0424.0 • 2019-04-23