EN
5. CONTROL PANEL
5.1 MAIN SCREEN
When the blast chiller is electrically powered, the screen displays the main screen (shown below) from which it is
possible to access various blast chilling or freezing modes.
The main screen icons are:
BLAST CHILLING icon.
Pressing this icon gives access to the different chilling mo-
des at +3 °C.
DEEP FREEZING icon.
Pressing this icon gives access to the different freezing
modes at -18 °C.
FISH SANIFICATION icon.
For this function only the probe control is provided.
ICE CREAM HARDENING icon.
Pressing this icon gives access to the 2 different ice cream
hardening modes; ICE SOFT and ICE HARD.
EXTRA icon.
Pressing this icon gives access to complementary (defrost
and pre-cooling) or specific functions (bottle cooling or
chamber sterilization).
5.2 BLAST CHILLING AND CONSERVATION
Pressing the BLAST CHILLING icon on the main screen, the
system shows the screen on the side. In this screen it is
possible to select the type of blast chilling control between:
• Blast chilling with probe control
• Blast chilling with time control.
In both cases, at the end of the chilling phase the blast
chiller automatically switches to a conservation phase for
an indefinite time.
The system proposes chilling with probe control by default
(the probe icon is highlighted).
The system also proposes the choice between:
• Soft blast chilling (proposed by default)
• Hard blast chilling
The soft cycle is divided into the following phases:
• blast chilling
• conservation
The hard cycle is divided into the following phases:
• hard blast chilling
• blast chilling
• conservation
24