Display And Keypad; Function Keys - SJE Rhombus VARIOspeed LCD Manual De Inicio Rápido

Para aplicaciones de presión constante
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Display and Keypad

Monitor Backlit LCD
MENU: To display
parameters and
drive data.
Monitoring Hz, Amps and PSI
Press the MON button to return
to the main monitor display:
Example: Changing the Set Pressure
1. Press MENU then F3 to choose the parameter setting mode.
2. Turn the SETTING DIAL until P.133 (Pr.No. 0133) appears.
3. Press F2 (SET) to read the current pressure set point value. "60.00" appears.
4. Turn the SETTING DIAL to change the Preset value to the pressure set point value "65.00".
5. Press F2 (SET) to save. Flash --- Parameter setting complete!
• Press F1 (BACK) twice
• Turn SETTING DIAL to read another parameter
• Press F2 (SET) to show the setting again.
• Press F3 (NEXT) to show the next parameter.
• Press MON to return to the main monitor display.
VARIOspeed
®
LCD Quick Start Manual
DISPLAY:
- Pressure
- Motor speed
- Motor Amps
SETTING MODE
P r. N O .
(The parameter number
0000
read previously appears.)
———
STOP
EXT
BACK
SET
S E T T I N G M O D E
P r. N O .
0133
———
STOP
EXT
BACK
SET
133 PIDVal
Current
60.00PSI
Preset
60. 00PSI
———
STOP
EXT
BACK
SET
NEXT
133 PIDVal
Current
60.00PSI
Preset
65. 00PSI
———
STOP
EXT
BACK
SET
NEXT
133 PIDVal
Current
60.0 0PSI
Preset
65.0 0PSI
Completed
———
STOP
EXT
BACK
SET
NEXT
14:32
PIDval2
61.7PSI
Hz Out
0.00Hz
I Out
0.00A
———
STOP
EXT
PREV
SET
NEXT
FUNCTION KEYS: Used to nav-
igate through parameters, moni-
tored data, and save changed
parameters.
STOP/RESET:
Fault RESET
SETTING DIAL: Used
to scroll through
parameter list and edit
parameter value.
3

Publicidad

Tabla de contenido
loading

Productos relacionados para SJE Rhombus VARIOspeed LCD

Tabla de contenido