Parameter List - SJE Rhombus VARIOspeed LCD Manual De Inicio Rápido

Para aplicaciones de presión constante
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Parameter List

PARAMETERS
Basic Setup
P. 2
Minimum Frequency
P. 9
Motor Amps
P. 19
Motor Voltage
P. 44
Acceleration Time
P. 45
Decceleration Time
P. 133
Set Point Pressure
P. 575
Sleep Time
P. 576
Sleep Frequency
P. 577
Start Press. Differential
Advanced Setup
P. 4
HAND Frequency
P. 7
1st Acceleration Time
P. 8
1st Deceleration Time
P. 147
Thrust Bearing Switch Frequency (Well Pump)
P. 125
Maximum Frequency
P. 131
High Pressure Alarm
P. 1370
High Pressure Delay Time
P. 129
PID Proportional Band
P. 130
PID Integral Time
P. 935
Press. Sensor Max. Range
Advanced Pumping Functions
P. 127
Pre-charge Frequency
P. 761
Pre-charge ending level
P. 762
Pre-charge ending time
P. 1361
Detection Time for PID Output Hold
P. 1362
PID Output Hold Range
P. 1366
Sleep Boost Level
P. 1367
Sleep Boost Wating Time
P. 1368
Output Interruption Cancel Time
Caution! Always set Pre-charge Pressure (P.761) below the pressure set point (P.133). It is recommended for the Pre-charge pressure to be set at
least 20PSI below the pressure set point, even when only using Pre-charge timer.
*A setting of 9999 indicates the function is disabled.
1. Basic setup:
Minimum Frequency (P. 2)
The Minimum Frequency should be set to the minimum output frequency that the pump should be allowed to run.
Contact your pump manufacturer to obtain the pump safe operation ranges. Default value: 30.00Hz
Motor Amps (P. 9)
The VFD's electronic overload will signal an overload fault and protect the motor from damage in the event of an over-
load condition. Set the Motor Amps setting to the motor nameplate Full Load Amps for non-submersible pumps and to
the Motor Max Amps for submersible pumps. Default value: (motor nameplate)
Motor Voltage (P. 19)
Set the Motor Voltage setting to the voltage rating found on the motor nameplate. This value must not exceed the volt-
age of the incoming power. Default value: (same as incoming power)
Acceleration Time (P. 44)
Set the Acceleration Time to the rate at which the output frequency will accelerate while the VFD is operating above the
Thrust Bearing Switch Frequency. This time is based on the time the VFD would take to accelerate between 0 Hz to 60
Hz. Default value: 5 sec
VARIOspeed
®
LCD Quick Start Manual
DESCRIPTION
RANGE
DEFAULT
0-120.00Hz
30.00Hz
0-500.0A
XXX.XA
0-1000.0V
0-3600.0s
0-3600.0s
0-200.00PSI
55.00PSI
0-3600.0s
0-590.00Hz
35.00Hz
900.0-1100.0%
1005.00%
0-590.00Hz
50.00Hz
0-3600.0s
0-3600.0s
0-590.00Hz
30.00Hz
0-120.00Hz
60.00Hz
0-100.0%
95.0PSI
0-900.0s
0.1-1000.0%
100.0%
0-3600.0s
0-500.00PSI
200.00PSI
0-590.00Hz
0-100.0PSI
0-3600.0s
0-900.0s
0-50.0%
0-100.0%
0-360.0s
0-360.0s
9999
5.0s
5.0s
10.0s
2.0s
2.0s
2.0s
1.0s
9999
9999
9999
5.0s
9999
9999
0.0s
0.0s
5

Publicidad

Tabla de contenido
loading

Productos relacionados para SJE Rhombus VARIOspeed LCD

Tabla de contenido