Usage
Open the case and remove the battery activation
strip. Self-testing will start for 30 seconds.
When the sensor is in operation, if it is triggered
more than twice within 3 minutes, it will switch
Connect Button
to standby mode to save power. If no movement
is detected within the next 3 minutes, the sensor
goes back to working mode.
Register in the control panel
Navigate through the menu of the control panel and reach
"ADD A
NEW" (Wireless Sensor).
Press the Connect button at the back of the motion sensor or trigger the sensor (by moving in
front of it) to register the detector in the control panel.
To check if the registration is complete, refer to the instructions in the table on page 10
"TEST
MODE".
Installation
Avoid mounting the detector close to windows, air conditioner, heater, refrigerator, oven,
sunshine and places where the temperature changes fast or where the air stream flows
frequently.
If two detectors are installed in the same detection scope, adjust the location to avoid
interferences and false alarms.
Top
Fix the bracket on the wall with screws
and attach the detector to the bracket.
Adjust the bracket to change the
2.2 m
detection distance and angle. It is
recommended to mount the detector
2.2 m from the ground.
Ground
Bottom
The detector is more sensitive to
Side view
Top view
cross
movements
than
vertical
movements.
27