Current measuring
Never try to measure current when the voltage between the open circuit and the
ground is higher than 250V.
Never place the test cables in parallel with a circuit or component when they are
connected to the terminals.
1. Remove the power supply and dischar-
ge the capacitors of the circuit.
2. Adjust the knob to current measuring
range µA / mA / A.
3. Insert the black connector into the COM
terminal.
To make a measuring under than 400 mA
insert the red connector into
to measure between 400 mA and 10 A
insert it in A terminal.
4. Open the circuit. Connect the tips in the
circuit in a way the current to flow through
of multimeter (serial connection).
5. Activate the energy in the circuit again.
Press
to change to AC.
36
terminal;