Gree GCF220BKNA Manual Del Usuario página 25

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The humidity shows
is always high
The humidity shows on the
room hygrometer is not the
same as the one shows on
unit.
The humidity is not
increased.
The humidifying does
not stop operation even
when the room humidity
is high.
Too much water on air
outlet
Water splashed to
the fl oor
The TV display is
disturbed.
Dual-8 nixie tube
displays L1
Dual-8 nixie tube
displays F1
Dual-8 nixie tube
displays 00
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
If the unit is placed by window or a location
facing cold air?
The environment humidity is high.
―Move the unit to other place.
The room located in north or beside the bathroom
is with a high humidity.
The humidity and temperature will be fl uctuated
in the room as air fl ow. Please take humidity
display on unit for reference.
The humidity is hard to increase as the low
indoor temperature, and the dry wall and fl oor.
If the unit is used in a room with larger area than
the rated applicable one?
Is the airfl ow volume strong enough?
―Set the humidity mode as"auto"or "consecutive"
and the air fl ow volume at high before operation.
Is the setting humidity is too high?
Does the unit suffer direct sunshine or warm air?
―Move the unit to other place.
The humidifying operation is together with
purifying. When the humidify reaches set value,
humidifying will stop while purifying keeps
operation.
Regulate the shape of fi lter and well assemble it.
Incorrectly assemble might cause water leakage.
Is the unit inclined?
―Inclined unit might cause water splashing.
Stop operation when moving the unit, pour out
the water in water tank and water tray.
Is the cover of tank loosened?
―Properly cover the tank.
Is the unit placed closely to the TV or TV
antenna?
Is the power cord or antenna placed closely to
the unit?
―Please keep the unit far away from the TV,
radio and antenna.
Humidity sensor is short-circuited.
Replace the humidity sensor.
It's the malfunction of humidity sensor or
connection wire of humidity sensor is loosened.
Replace the humidity sensor.
Ambient humidity is lower than 30%RH.
―it's not malfunction
Humidity sensor is broken-circuited. If it still
displays 00 when humidity is higher than 30%.
―Please contact after-sales service.
23

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Gcc240bknaGcs260bkna

Tabla de contenido