Problem
Icemaker is not
making enough ice
(continued).
Dispensing water
slowly.
Not dispensing ice.
Possible Causes
Doors are opened often or for long
periods of time.
Doors are not closed completely.
The temperature setting for the
freezer is too warm.
Water o lter has been exhausted.
Reverse osmosis o ltration system is
used.
Low house water supply pressure.
Doors are not closed completely.
Infrequent use of the dispenser.
The delivery chute is clogged with
frost or ice fragments.
The dispenser display is locked.
Ice bin is empty.
If the doors of the unit are opened often, ambient
air will warm the refrigerator which will prevent the
unit from maintaining the set temperature. Lowering
the refrigerator temperature can help, as well as not
opening the doors as frequently.
If the doors are not properly closed, ice production
will be aç ected. See the Doors will not close
completely or pop open section in Parts & Features
Troubleshooting for more information.
The recommended temperature for the freezer
compartment for normal ice production is 0°F. If the
freezer temperature is warmer, ice production will be
aç ected.
It is recommended that you replace the water o lter:
• Approximately every 6 months.
• When the water o lter indicator turns on.
• When the water dispenser output decreases.
• When the ice cubes are smaller than normal.
Reverse osmosis o ltration systems can reduce the water
pressure below the minimum amount and result in
icemaker issues.
If the problem persists, it may be necessary to contact
a plumber.
The water pressure must be between 20 and 120 psi
(138 - 827 kPa) on models without a water o lter and
between 40 and 120 psi (276 - 827 kPa) on models
with a water o lter.
If the problem persists, it may be necessary to contact
a plumber.
Ice will not dispense if any of the refrigerator doors
are left open.
Infrequent use of the ice dispenser will cause the cubes
to stick together over time, which will prevent them
from properly dispensing. Check the ice bin for ice
cubes clumping/sticking together. If they are, break up
the ice cubes to allow for proper operation.
Eliminate the frost or ice fragments by removing the
ice bin and clearing the chute with a plastic utensil.
Dispensing cubed ice can also help prevent frost or ice
fragment buildup.
Press and hold the Lock button for three seconds to
unlock the control panel and dispenser.
It may take up to 24 hours for each compartment to
reach the desired temperature and for the icemaker
to begin making ice. Make sure that the shutoç (arm/
sensor) is not obstructed.
Once the ice supply in the bin has been completely
exhausted, it my take up to 90 minutes before
additional ice is available, and approximately 24
hours to completely reo ll the bin.