Description Of The Leds In The Circuit; Description Of The Buttons In The Circuit - Vimar RS10 Manual Para El Conexionado Y El Uso

Tarjeta con pantalla 230 vac para cancela corredera
Ocultar thumbs Ver también para RS10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44
RS10
3.10 - Connecting the aerial:
The 17 cm rod is supplied pre-wired, to increase the range connect the aerial, as shown in the figure:

4 - Description of the LEDS in the circuit

Abbreviation Colour LED status
Off
OPEN
Red
On
Off
APCH
Red
On
Off
APED
Red
On
Off
STOP
Green
On
Off
PHOTO
Green
On
Off
STPA
Green
On
Off
FCAP
Green
On
Off
FCCH
Green
On
DL1
Red
Fast blink

5 - Description of the buttons in the circuit

Abbreviation
AP/CH
Controls opening and closing the gate
ESC
Exit or go back to the lower level of the menu
▲ UP
Increases the displayed value by one unit or scrolling on the same menu level
▼ DOWN
Decreases the displayed value by one unit or scrolling on the same menu level
OK
Confirms the value or moves to the top level of the menu
Preliminary check:
After powering up the control unit, the display shows the name of the control unit RS10, the firmware version Fxxx and then switches off. Check the
diagnostic LEDs of the inputs, the STOP, PHOTO, STPA, FCAP and FCCH LEDs must be on (if the limit switches are not engaged).
20
5
Terminal status
APRI input (terminal 16) not engaged
APRI input (terminal 16) engaged
APCH input (terminal 18) not engaged
APCH input (terminal 18) engaged
APED input (terminal 19) not engaged
APED input (terminal 19) engaged
STOP input (terminal 21) engaged
STOP input (terminal 21) not engaged, if not used then jumper between COM and STOP terminals
PHOTO input (terminal 22) engaged (photocell beam interrupted)
PHOTO input (terminal 22) not engaged, if not used then jumper between COM and PHOTO terminals
STPA input (terminal 23) engaged (sensitive edge pressed)
STPA input (terminal 23) not engaged, if not used then jumper between COM and PHOTO terminals
FCAP input (terminal 13) engaged. The gate is in the position of:
Opening limit switch if parameter P18 = R (opening to right)
Closing limit switch if parameter P18 = L (opening to left)
FCAP input (terminal 13) not engaged.
FCCH input (terminal 15) engaged. The gate is in the position of:
Closing limit switch if parameter P18 = R (opening to right)
Opening limit switch if parameter P18 = L (opening to left)
FCAP input (terminal 15) not engaged.
Flashes quickly if one of the inputs is engaged
EN
Fig. 13
Description

Publicidad

Tabla de contenido
loading

Tabla de contenido