FOR OPERATION WITH A MAINS FREQUENCY OF 60 HZ FOLLOW THE INSTRUCTIONS:
- disconnect the power supply to the control unit
- press the UP and DOWN buttons simultaneously
- power up while keeping the buttons pressed until the display shows 60 H
To return the control unit to operate at 50 Hz repeat the procedure, the display will show 50 H.
6 - Full description of the programming menu
The programming menu is divided into 3 levels: first the main level, second the parameters level and third the values level
Main menu:
Display Message
Description
LRNE
Learning travel with quick programming (see section 7)
RAD
Remote control management
LRN
Learning travel with custom programming
PAR
Used to modify all the parameters of the control panel
DEF
Used to return to the default values of the parameters menu
CNT
Used to view the manoeuvres carried out
PASS
Used to enter a 4-digit password
After selecting the desired item from the main menu by pressing the UP or DOWN button, confirm by pressing OK.
6.1 - LRNE: quick procedure for programming gate travel
N.B.: Before you start programming, check parameter 18 (opening direction)
If the gate opens to the right, set parameter 18 (opening direction) to R.
If the gate opens to the left, set parameter 18 (opening direction) to L
APERTURA
OPENING
APERTURA
OPENING
EN
Parameter 18
on R
Parameter 18
on L