6.7 - PASSWORD:
it is possible to enable a password on 3 levels, with level 1 the password is required to enter the PAR, DEF, LRNE and LRN menu,
with level 2 the password is required to enter the RAD menu, with level 3 the password is required to enter all the menu items (LRNE, LRN, DEF, RAD,
CNT, PAR, ERR).
N.B.: If you forget the password, you need to call the support centre
Example of entering password 4-3-2-1 at the second level:
x8
x4
x4
A password is required every time you try to access the main menu (on pressing the Up or Down button the display will show PASS, you need to enter the
password to display the main menu).
If a password of level 1 or 2 is entered, when you select the protected menu item you will be prompted for the password, enter the password and confirm
with OK, if you exit the menu you will be prompted for the password.
If the password is incorrect the display will show NO.

7 - Error messages

Message
Description
F02
Detected an obstacle during the opening movement
F03
Detected an obstacle during the closing movement
F04
PHOTO input contact open
F06
STPA input contact open
F09
Maximum opening or closing time elapsed
F11
PHOTO input test failed
F12
STPA input test failed

8 - Troubleshooting

Problem
Automation does not work
You cannot save the remote controls Batteries of the remote control discharged
You cannot enter travel
programming
As soon as the gate starts it stops
and reverses
During slowdown, the gate stops and
reverses
The gate stops a few centimetres
after the limit switch has tripped
26
x2
x3
x3
Cause
No mains supply
Blown fuses
Control and safety inputs not working
Remote control not compatible with the first
one saved
Reached memory saturation
Safety devices open
Low acceleration on starting
Encoder not detected
Slowdown speed too low
High inertia
x2
x2
Solution
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis LEDs (STOP, STPA and PHOTO must be on)
Replace the batteries
The first saved remote control configures the control unit to save
only rolling-code remote controls or only dip-switch remote con-
trols
Delete at least one remote control or add an external receiver
(maximum capacity 128 remote controls)
Check the diagnosis LEDs (STOP, STPA and PHOTO must be on)
Increase parameter 15 and 16 (motor force and force on obsta-
cle) and set parameter 24 On (break-out on starting)
Check the encoder connector is properly inserted or if there is no
encoder insert the jumper in connector CN6 (the control unit is
configured to operate with or without the encoder when program-
ming the travel)
Increase parameter 13 and 14 (slowdown speed on opening and
closing)
Increase the value of parameter 17 (braking power)
EN
x1
x1

Publicidad

Tabla de contenido