Setting Functions And Options; System Setup - Honeywell Home Smart Serie Guia Del Usuario

Ocultar thumbs Ver también para Smart Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Setting functions and options

You can change options for a number of system functions. Available functions depend
on the type of system you have. The functions, along with available options, are
described on pages 18–19.
This thermostat is pre-set for a single-stage heating/cooling system. Setting function
1 for a heat pump will adjust the default settings.
1 Press
Fan
and
for approximately 3 seconds. The screen
will change to display two numbers and
the button designations will be Done, Back,
blank, Next.
Next
2 Press
until you see the function
number—the larger number on the left—
you want to set.
3 Change options for any function by
pressing
or
s
(smaller number on right) is displayed.
4 Repeat Steps 2 and 3 until you have set all
functions that you wish to change.
5 When you have made all changes, press
Done
to save and exit.

System setup

Function
1
Select System
Type
If you are not sure
of your heating/
cooling system
type or have other
questions, go to
honeywellhome.
com
2
Heat Pump
Changeover Valve
(for heat pumps
only)
3
Heating Fan
Control
69-2715EF—07
simultaneously and hold
s
until the correct option
t
Settings & Options
0
Heat/cool: Gas, oil or electric heating with central air conditioning.
1
Heat pump: Heat pump without backup or auxiliary heat.
Heat only: Gas, oil or hot water heat without central air conditioning.
2
3
Heat only with fan: Gas, oil or electric heat without central air
conditioning.
4
Cool only: Central air conditioning only.
5
Heat pump: Heat pump with backup or auxiliary heating.
6
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2
cooling stages (wires on Y and Y2).
7
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1
cooling stage (wire on Y).
8
Heat/Cool Multiple stages: 1 heat stage (wires on W), 2 cooling
stages (wire on Y and Y2).
0
Cooling changeover valve: Use this setting if you connected a wire
labeled "O" to the O/B terminal.
1
Heating changeover valve: Use this setting if you connected a wire
labeled "B" to the O/B terminal.
0
Gas or oil heat: Use this setting if you have a gas or oil heating system
(system controls fan operation).
1
Electric heat: Use this setting if you have an electric heating system
(thermostat controls fan operation).
18