Adjust the stops of the end positions statically according to the type.
S
If possible, use symmetric angle settings
S
that follow the line of symmetry of the
DSMI.
These produce a more even movement
between right−hand and left−hand swive
ling movements.

Adjusting the stops on the DSMI

Note
Operating the DSMI without cushioning will destroy it.
S Make sure that the DSMI is always only operated with shock absorbers
(electronically controlled, internal or external).
S Make sure that the locking screws aB of the shock absorber retainers are
retightened with the specified tightening torque.
S Observe the instructions in the descriptions of the positioning controller
when adjusting the stops.
For use as a measuring cylinder:
S Replace the adjustment sleeves with cushioning elements (elastomer
shock absorbers or shock absorbers è Accessories" chapter). Observe
the enclosed documentation.
1. Remove the cover cap of the DSMI from the housing (if present).
2. Swivel the moving mass to the desired
end position.
If the DSMI is depressurised, this can be
done by hand or using a hexagon spanner
on the swivel lever aA.
The angle scale can be used for precise
positioning.
DSMI−...−B
Graduation (1 graduation mark =)
Fig. 10