LOGICS WITH MICROPROCESSOR
STATUS OF INPUTS SIGNALLED BY LEDs
"PEDESTRIAN GATE" FUNCTION
INCORPORATED FLASHING CIRCUIT
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
RECEIVER CONNECTOR
BATTERY AND BATTERY CHARGER CONNECTOR (OPTIONAL)
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input). The
go off only when the controls to which they are associated are operated.
All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The light
up only when the controls to which they are associated are operated.
Board power supply
Max motor 1 power DC
Max motor 2 power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor 1 protection (F2 - 5x20)
Fast acting fuse for motor 2 protection (F3 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
DL1
PEDESTRIAN button red LED signal
DL2
OPEN/CLOSE button red LED signal
DL4
STOP button green LED signal
DL5
INTERNAL PHOTOCELL green LED signal
DL6
EXTERNAL PHOTOCELL green LED signal
14
CONTROL PANEL FOR ONE-TWO 12V MOTORS WITH ENCODER
D747M
English
TESTING
13,5 Vac - 50 Hz
50 W - 18 Vdc
50 W - 18 Vdc
F 16 A
F 10 A
F 10 A
F 5 A
18 Vdc
18 Vdc
5 Vdc
-20 °C ÷ +70 °C
DIAGNOSTICS LED
TAU
Srl