Descargar Imprimir esta página

Layout And Components; Technical Specifications; Electric Connections - Genius JA574 Instrucciones Para El Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker
(Residual Current Device) with adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J3
connector of the equipment (see fig.2).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
2.

TECHNICAL SPECIFICATIONS

Power supply
Absorbed power
Motor max. load
Accessories max. load
Operating ambient temperature
Protection fuses
Function logics Automatic / Semi-automatic / "Stepped" safety devices /
Semi-automatic B / Dead-man C / "Stepped" semi-automatic
Opening/closing time
Pause time
Closing leaf delay
Opening leaf delay
Thrust force
Dip-switch adjustable on 8 levels for each motor
Terminal board inputs
Terminal board outputs
Rapid connector
Selectable functions
Opening and closing leaf delay - Reversing stroke -
Fail safe - Closing safety devices logic - Pre-flashing
Programming key
(independent work times + opening and closing deceleration)
4.

ELECTRIC CONNECTIONS

J3
1
PE N
L
OP
COM
M1
MAIN
M1
230 VAC
50 Hz
ATTENTION: when
connecting, observe
the sequence phase/
neutral.
NB.: Capacitors are supplied with the operators.
CONTROL BOARD JA574
230 V~ ( +6% -10%) - 50 Hz
10 W
800 W
0,5 A
-20 °C +55 °C
2 (see fig. 1)
Programmable (from 0 to 120 s)
0, 10, 20, 30, 60, 120 s
0, 5, 10, 20 s
2 s (Can be disabled with the dip-switch)
Open / Open free leaf / Stop /
Opening safety devices / Closing safety
devices / Power supply + Earth
Flashing lamp - Motors -
24 Vdc accessories power supply - Fail safe
Rapid connector 5 pins
Logics and pause times - Thrust force -
Simple or Advanced work time learning
2
3
4
5
6
7
8
OP
COM
CL
LAMP
M2
C1
C2
230 VAC
M2
max.60W
TOTALLY OPEN
OPEN LEAF 1
3.

LAYOUT AND COMPONENTS

F1
F1
J3
J3
1
L
PE N
COM
MAIN
Led OP_A TOTALLY OPEN LED
Led OP_B LED: OPEN LEAF 1 / CLOSE
Led STOP LED STOP
Led FSWCL LED: CLOSING SAFETY DEVICES
Led FSWOP LED: OPENING SAFETY DEVICES
DL10
J1
J2
J3
J4
F1
F2
F
D S 1
D S 2
J1
J4
9 10 11 12 13 14 15 16 17 18 19
A
B
CL OP
STP
OPEN
FSW
STOP
9
F2
F2
OP_A
STOP
J4
J4
J1
2
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19
OP
OP
A
B
CL OP
STP
COM
CL
LAMP
M2
M1
OPEN
FSW
LED: TIME LEARNING SIGNALLING
LOW VOLTAGE TERMINAL BOARD
RAPID CONNECTOR 5 PINS
230 VAC POWER SUPPLY TERMINAL BOARD
MOTORS AND FLASHING LAMP CONNECTION TERMINAL
BOARD
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F
5A)
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
TIME LEARNING SELECTION PUSH-BUTTON
1ST GROUP OF MICROSWITCH PROGRAMMING
2ND GROUP OF MICROSWITCH PROGRAMMING
+
+
-TX
-
-
-
+24V
FSW
For connection of
the photocells
and safety
devices, see
paragraph 4.1.
ENGLISH
DS2
DS1
1
2 3 4
5 6 7 8
9 10 11 12
1 2 3 4
J2
J2
F
DL10
DL10
F
OP_B
Led
FSWCL
FSWOP
J1
+
+
-TX
-
-
-
+24V
FSW
Fig. 1
Fig. 2

Publicidad

loading