Bosch DND Serie Instrucciones De Instalación página 10

Ocultar thumbs Ver también para DND Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED
Figure 8
B. FOR INSTALLATION WITH ANOTHER BRAND OF COOKTOP (Figure 8)
Have the following cooktop measurements available before
proceeding All cooktop dimensions should be verified
through measurement prior to cutting the countertop:
CCW = Cooktop Cutout Width
CCD = Cooktop Cutout Depth
COW = Cooktop Overall Width
COD = Cooktop Overall Depth
with the above dimensions confirmed, determine the cutout
size as follows:
1. Find the cutout width, (CW):
If CCW is smaller than the DHD cutout width then:
Installation
CW
DHD8005UC
28
DHD9605UC
34
If CCW is larger than the DHD cutout width then:
CW = CCW
See Figure 8 for DHD cutout widths and dimension
definitions.
3
/
8
/
3
8
2. Calculate the cutout depth, CD:
Determine the cooktop overhang (CO)
CO = (COD-CCD)/2 (Assumes front and rear cooktop
overhangs are equal) Calculate the cutout depth, (CD):
CD = COD - CO+1-
3. Determine setback (SB) distance from front of
countertop to front of cutout. SB is specified in the
installation instructions shipped with the cooktop.
4. Backsplash thickness must not exceed BT as
calculated below:
BT = 24
/
" - OD-SB+CO
7
8
(Provides
/
" clearance between vent and backsplash.)
1
8
A negative value for BT means countertop is too small
for the installation.
5. Verify that the available flat countertop has a width
greater than OW and a depth greater than OD.
OW depends on the installation:
DHD8005UC: OW equals the greater of COW or 30".
DHD96005UC: OW equals the greater of COW or 36".
OD is determined by: OD=COD+2
6. Cut countertop using dims: CD, CW and SB as
defined in Figure 8.
Page 8
2 1/4"
/
"
7
8
1
/
".
8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dhd9605uc

Tabla de contenido