Install Range Hood Internal Blower - ELICA ECP136SS Guía De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Install Range Hood Internal Blower (Not included)
1
Remove grease filters from range hood. See the
"Maintenance" section in the Use and Care Guide.
2
Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the front or
top for the dual motor system.
A. Wiring connection
3
Slide the left mounting plate flange under the motor
mounting bracket.
B
A
A. Motor mounting bracket
B. Mounting plate left flange
4
Run the power supply wires and connector from the
range hood terminal box and connect it to the motor
electrical plug.
A
A. Motor Electrical Plug
B. Power supply wires and connector
10
5
A
6
7
B
Push the right end of the motor mounting plate up and
snap it into the spring tab.
NOTE: The spring tab should be outside the slot in the
mounting plate.
A. Motor mounting
Align mounting holes and install 6 x 16 mm screws and
6.4mm lock washers
A
B
A. Screw with lock washer
B. Mounting hole
Attach power supply connector from the range hood to
the connector on the blower motor assembly wiring box.
A
B
A. Blower motor power supply connector
B. Range Hood power supply connector
A
B
plate
B. Spring clip

Publicidad