Once the Universal Mount is attached to the bottom of the SP5, the unit can
be mounted on a 1/4" x 20 thread camera tripod, a 5/8" x 11 surveyor's tripod
or attached to any ferrous metal surface (such as steel studs) by using the
magnets located on the rear and bottom side of the mount, or fixed thanks to
the strap (supplied) to wood studs, etc.
Trivet – (Fig. C) Platform with 3 legs used for down plumb alignment jobs
(such as framing and drywall installation).
Target – This target is used for enhancing the visibility of the laser dot.
Strap – This strap is used for mounting the universal base to any object 17,80
cm or smaller in diameter, in order to ensure the safety of the instrument, if
mounted on an unstable surface.
Carrying Case – The soft sided carrying case provides ample storage for the
SP5, target, universal mount, laser glasses (not supplied), manual and 1
spare set of batteries (not supplied). The case can be belt mounted or comes
with a carrying strap and handle for easy handling.
APPLICATIONS
PLUMB (Fig. D)
Place the SP5 on the floor or a fairly level surface near the wall or the object
to be plumbed. Measure from the wall being plumbed to the laser beam at
two points. One point near the SP5 and another point farther away. (Note:
the greater the distance between the two points the greater the possible
accuracy).
If the measurements of the two points are the same, then the surface is
plumb. If not, pull the wall in or push it out until the upper and lower meas-
urements are equal.
If you want to transfer a point from the floor to a point on the ceiling or vice-
versa, mount the SP5 on the universal mount.
Move the SP5 until the point you wish to transfer is centered on the laser
dot. Mark the other point as required.