Best WM45I Manual De Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
Controls
The hood is operated using the (5) push buttons located
on the front edge of the hood. Fig. 1.
The Light On/Off switch turns the lights on to high intensity and turns them off.
The Light Dimmer
switch alternates light intensity from low to high.
The Blower Off/Speed switch turns the blower off and changes blower speed to four different
speed settings: high, medium-high, medium-low and low speed. Depress and hold the button
for 2 seconds to turn the blower off.
The Blower On/Speed switch turns the blower on to four different speed settings: Low,
medium-low, medium-high and high speed.
The Blower LED Indicators illuminate for each selected speed.
The Time Delay switch activates a delay off feature. When pushed, the blower will continue
to operate at the current speed setting for 10-minutes before automatically turning itself off.
The LED (on the right) flashes during operation.
The LED (on the right) is also used as a filter clean reminder. It will flash after 30 hours of
operation - indicating the need to clean the filters.
The Filter Alarm Reset switch is used to reset the 30-hour filter timer. After filters are cleaned
or replaced, press this switch once to reset the filter clean alarm.
LED
Blower LED
Time Delay /
Indicators
Filter Alarm
Light
Light
Blower
Blower
Reset
On / Off
Dimmer
Off / Speed
On / Speed
FIG. 1
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When
this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the
blower, do it from the main electrical panel.
- 4 -

Publicidad

Tabla de contenido
loading

Tabla de contenido