PULSE / SYNERGIC control panels
IGC status and calibration
Visible only if IGC kit is installed.
Press the
-key to start IGC calibration. Use the right
control knob to switch between manual and synergic gas
control if a synergic MIG program is selected:
0: Manual gas control
1: Synergic (IGC) gas control
Setting remote control
Use the right control knob to change the
following settings:
0: Disabled
1: Dialog torch
2: Analogue remote control
4: MIG-A-Twist V2 (November 2010)
5: MIG-A-Twist V1
6: ERGO2 1–7 sequences
7: ERGO XMA 1–3 sequences
Options menu for machine settings
Press the
and return to the main menu.
Long Cable Compensation - status and
calibration
Press the
-key to start cable calibration.
Use the right control knob to enable/disable
Long Cable Compensation:
0: Disabled
1: Enabled
Reduction of the adjustable range for
voltage setting (synergic MIG/MAG)
The adjustable range for voltage trim can be
reduced by 0-50% of the synergic voltage. This
feature is used if the machine is locked in level 2
and disabled when "---" is displayed.
Reduction of the adjustable range for
current setting (MMA/synergic MIG/MAG)
or wire feed speed (manual MIG).
The adjustable range for current setting can be
reduced by 0-25% of the synergic current. This
feature is used if the machine is locked in level 2.
-key to exit the OPt-menu
FIXED FUNCTIONS
Some functions are fixed and cannot be connected and
disconnected from the display.
Anti-freeze (MMA)
The anti-freeze function is active in MMA. In MMA it
happens that the electrode sticks to the workpiece. This
is registered by the welding machine, and the current
is lowered to 10 A after 1 sec., which makes it easier to
break off the electrode. Welding can then be continued.
Stop of gas flow in case of fault detection
The machine automatically stops the gas flow to the
torch, turns off the welding current in order to let a
possible arc extinguish and stops the wire feeding in case
of a fault.
Automatic stop of re-ignition (MIG/MAG)
In case of missing arc during ignition, re-ignition is
automatically stopped after 4 sec.
The arc extinguishes
Welding stops and gas post-flow begins, if the arc
extinguishes during welding. The arc can be re-established
when triggering the torch again.
Read-out of software version during start-up
Press and hold the
-key until
displayed in the left display when the machine is switched
on. Release the key and turn the left control knob to
switch between display of licence number and software
version for:
1: Control box
2: Welding program
3: Welding control
Press the key
(4A) to return to normal display and
start welding.
(licence number) is
17